Currently it only shows your basic business info. Start adding relevant business details such as description, images and products or services to gain your customers attention by using Boost 360
android app
/
iOS App/ web portal.
{
"products": [
{
"_id": "5ba34a638be1ca00010f1a22",
"fptag": "APPLIEDTECHNOSYSTEMS",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Chlorine Gas Detector",
"description": "With thorough understanding of the relevant industry, we are offering a wide range of Fixed Gas Detection System. It is suitable for Combustible gases (%LEL) or PPM level of CO,H2S, SO2,NO,NO2,CL2,B2H6, Hydrocarbons, organic solvents and other Toxic Gases. This system is manufactured using best quality raw-material and highly developed technology. In tune with different needs of our copious clients, we customize the entire range in different sizes and other related specifications. Our offered range has gained exceptional value amongst our clients for its defined features.\n\nFeatures:\n\n•Precisely designed \n•Sturdiness\n•Long operational life\nOther Details:\n\n•Model ATS-105M is Single Point Hazardous Gas Monitor/ Alarm for ambient air. Model ATS-105 is suitable for Combustible gases (%LEL) or PPM level of CO, H2S, SO2, NO, NO2, CL2, B2H6, Hydrocarbons, organic solvents and other Toxic Gases. \n•The ATS-105M features a rugged, long-life Electrochemical, Catalytic Pellister, metal oxide semiconductor (MOS) sensor. \n•The sensor is available either in a separate junction box for remote mounting up to several hundred Meters from the monitor, or as an integral component attached to the instrument. \n•The ATS-105M provides a Graphics LCD display of gas concentrations, audio/visual alarms, relay contacts, plus analog (4-20mA ) and digital RS 232/485 and USB outputs. Accept Single 4-20 mA Input from Remote Sensor/Transmitter. \nSpecification:\nPrinciple Electrochemical, Solid State Semiconductor Catalytic and PID\n\nRange PPM/PPB or mg/M3\n\nResolution 0.1 Unit or 1 Unit (Application based)\n\nSampling Method Diffusion\n\nDisplay 128 X 64 Graphics LCD\n\nAlarm Relay Contact NO+NC\n\nAnalog out Put 4-20mA\n\nDigital out Put RS 232, RS 485 and Modbus Communication Protocol\n\nPower Source 230V AC\n\nAccuracy +/2%\n\nResponse Time\n\nData Storage 1000 or 10000\n\nSensor Life 2-3 Years\n\nEnvironmental\n\nTemperature 15 degree Celsius\n\nHumidity < 85%RH\n\nAtmosphere Pressure 86- 106Kpa\n\nDimension in mm 210 (W) X 180(H) X 110(D)\n\nWeight 1.2 KG\n\nWarranty One Year",
"price": 36500.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 7,
"_keywords": null,
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 72,
"imageuri": "https://productimages.withfloats.com/actual/5c11f21ff323430001931f43.jpg",
"tileimageuri": "https://productimages.withfloats.com/actual/5c11f21ff323430001931f43.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2018-09-20T07:21:07.972Z",
"updatedon": "2018-12-13T05:46:07Z",
"buyonlinelink": null,
"producturl": "http://WWW.APPLIEDTECHNOSYSTEM.IN/products/chlorine-gas-detector/72",
"availableunits": -1.0,
"iscodavailable": true,
"isprepaidonlineavailable": false,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "Chlorine Leak Detector",
"tags": [
"Chlorine Leak Detector",
"Gas Leak Detector",
"Fixed Gas Leaak dETECTIOR"
],
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": null,
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": null,
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "5b7264446d82d50505b27998",
"fptag": "APPLIEDTECHNOSYSTEMS",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Oxygen Analyser",
"description": "Oxygen Analyzer Model ATS-208A\n\nFeatures\n\n· Micro controller based embedded intelligent instruments\n· Long Life Electrochemical sensor\n· Proven technology from gas analyser experts\n\n• ppm or % O2 levels\n\n• Hazardous area options\n\n• Choice of cells for different applications\n\n• Remote or integral sensor\n\n• Choice of sample systems\n\nApplications\n\n• Nitrogen generators\n\n• Inert gas systems\n\n• Air separation\n\n• Furnace atmospheres\n\n• Biogas\n\n• Gloveboxes\n\n• Gasification\n\n• Packaging\n\nThe ATS -208A oxygen analysers have numerous applications in processes requiring the precise measurement of oxygen level. In ppm or % levels, safe areas or hazardous ones, in various process conditions and in differing backgrounds there is a ATS – 208A configuration right for your needs. Options include a choice of outputs, AC or DC versions, alternative oxygen cells or sample conditioning.\n\nOxygen is measured in a wide variety of processes, to confirm its presence or absence. The most common application however is measuring oxygen as an 'impurity' in other gases, e.g. nitrogen generators. Oxygen is required in aerobic processes and also in situations that require user intervention, e.g. to ensure that it is safe to enter a chamber for maintenance work. Some processes will only run efficiently in the absence of oxygen, e.g. furnace atmospheres; others just require a low level of oxygen for safety reasons, e.g. inert gas blanketing.\n\nDifferent electrochemical cells are available to suit the application. The standard A cell has a broad range from high ppm to 50% oxygen. The ‘B’ cell is designed for accuracy at low ppm levels; it will also work at % levels (with a shorter lifetime). The ‘C’ cell is designed for use in % levels of oxygen in the presence of mildly acidic gases, e.g. carbon dioxide, while the ‘D’ cell is perfect for low ppm oxygen applications where hydrogen is present. Applied will be pleased to advise on which cell is most suitable for an application.\n\nA choice of configuration is available. The most convenient and economic is a standard analyser with the cell mounted on the rear. Alternatively, there is remote sensor housing complete with flowmeter and valve. Where cable lengths and/or hazardous area conditions are an issue, the transmitter can be located in the sensor housing\n\nDifferent sample conditioning systems are available, standard or bespoke, according to the process conditions. Filters, pumps and regulators can all be incorporated to deliver the sample in the correct condition. Bypass flow systems enable longer distances from process to analyser to be achieved. Applied engineers are ready to recommend the right system for you on receipt of the full gas stream specification.\n\nFor hazardous area applications the sensor may be mounted remotely in the hazardous area and safely connected via an zener barrier to the electronics unit in the safe area. Alternatively the electronics unit can be supplied in an Explosion proof enclosure.",
"price": 125500.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": [
"oxygen cells",
"low ppm levels",
"oxygen analysers",
"numerous applications",
"electrochemical cells",
"Oxygen Analyzer Model",
"sensor housing complete",
"208A configuration right",
"hazardous area conditions",
"Explosion proof enclosure",
"Long Life Electrochemical",
"various process conditions",
"Bypass flow systems enable",
"low ppm oxygen applications",
"hazardous area applications"
],
"isarchived": false,
"isavailable": false,
"applicationid": null,
"productindex": 39,
"imageuri": "https://productimages.withfloats.com/actual/5c11f4c337862000011ac467.jpg",
"tileimageuri": "https://productimages.withfloats.com/actual/5c11f4c337862000011ac467.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2018-08-14T05:10:28.232Z",
"updatedon": "2018-12-13T05:57:22Z",
"buyonlinelink": null,
"producturl": "http://WWW.APPLIEDTECHNOSYSTEM.IN/products/oxygen-analyser/39",
"availableunits": -1.0,
"iscodavailable": true,
"isprepaidonlineavailable": false,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": null,
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": null,
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "677908a2405e113af9505bad",
"fptag": "APPLIEDTECHNOSYSTEMS",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Dew Point Meter ATS303D",
"description": "The APPLIED ATS-303D Compact Dew Point Transmitter provides reliable and long term stable dew point monitoring in industrial applications. Provide clear readings and include additional features like data logging, alarms for critical thresholds, and wireless connectivity.",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 6,
"_keywords": [
"wireless connectivity",
"critical thresholds",
"additional features",
"data logging alarms"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 88,
"imageuri": "",
"tileimageuri": "",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2025-01-04T10:08:34.481Z",
"updatedon": "2025-01-04T10:08:34.481Z",
"buyonlinelink": null,
"producturl": "http://WWW.APPLIEDTECHNOSYSTEM.IN/products/dew-point-meter-ats303d/88",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": false,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": null,
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": null,
"paymenttype": "None",
"producttype": "products",
"hsncode": null,
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "6690f37b62369a1a08b058c3",
"fptag": "APPLIEDTECHNOSYSTEMS",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "INSITU ZIRCONIA BASED OXYGEN ANALYZER",
"description": "FEATURES \n1)Zirconia oxide sensor, giving real measurement of excess oxygen\n2. Long life zirconium Sensor\n3. Reliable out put , adaptable to close loop control\n4. Easy to Operate\n5. Wide Measurement Range 1PPM to 96%\n6. Easy installation, all hardware supplied with the system.\n7. Completely field repairable.\n8. Digital electronics package in IP 65 housing.\n9. Explosion-proof housing available as option.\n10. Auto & manual calibration facility for zirconium sensor.\n11. Micro controller based digital systems with user friendly\nAPPLICATIONS ·\nGas Manufacturing & Testing Petrochemicals & Chemical Industry ·\n· Exhaust Gas Analysis\n· Food Packing Factory\n· Monitor Vehicle Emission\n· Low oxygen Mesurment at industrial Process ·\n· Steel Plant Air Quality Monitoring, Oxygen Monitoring\n· Laboratories & Institutions\n· Metal Processing Plant\n· Petrochemical & Chemical Industries\n· Pharmaceutical Industries \nTECHNICAL SPECIFICATIONS\nPower supply :-24V ±10% Limited Power Supply\nPower consumption :-700mA maximum @ 24V\nAnalog outputs :-Single or Dual 420mA\nOutput ranges (oxygen) :-0— 25% vol.O2\nOutput ranges (pressure):- 750 — 1260mbar absolute\nRelays (SPST, N/O as std.):- 1 x system alarm (SPST)\n 1 x user configurable O set point alarm\nDigital communications :- RS485 Modbus RTU protocol\nDisplay :-16 character, 2 - line, backlit\n\nOPERATING CONDITIONS\nAmbient temperature:- 20 to +55°C (4 to +131°F)\nAmbient relative humidity :-95% RH\nGas composition Combustion gas from natural gas, biogas or oil\nSample gas temperature:- +700°C (1292°F)\nSample gas flow rate :-4m/s minimum recommended\nCompensated pressure :-750 — 1260mbar absolute",
"price": 230000.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": [
"5% RH",
"25% vol",
"65 housing",
"point alarm",
"natural gas",
"user friendly",
"excess oxygen",
"Analog outputs",
"Combustion gas",
"digital systems",
"Gas composition",
"Micro controller",
"real measurement",
"1 x system alarm",
"O2 Output ranges",
"Chemical Industry",
"Easy installation",
"Gas Manufacturing",
"Power consumption",
"Oxygen Monitoring",
"industrial Process",
"close loop control",
"Chemical Industries",
"Ambient temperature",
"Compensated pressure",
"OPERATING CONDITIONS",
"Exhaust Gas Analysis",
"Low oxygen Mesurment",
"Food Packing Factory",
"Sample gas flow rate",
"1 x user configurable",
"Digital communications",
"Wide Measurement Range",
"Sample gas temperature",
"Metal Processing Plant",
"Explosion-proof housing",
"1)Zirconia oxide sensor",
"1260mbar absolute Relays",
"Monitor Vehicle Emission",
"Dual 420mA Output ranges",
"Pharmaceutical Industries",
"Ambient relative humidity",
"Long life zirconium Sensor",
"Digital electronics package",
"manual calibration facility",
"RS485 Modbus RTU protocol Display",
"Steel Plant Air Quality Monitoring",
"TECHNICAL SPECIFICATIONS Power supply",
"INSITU ZIRCONIA BASED OXYGEN ANALYZER"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 75,
"imageuri": "https://bizimages.withfloats.com/actual/895d17c6f4da464e8654f534e6a43f67.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/895d17c6f4da464e8654f534e6a43f67.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2024-07-12T09:12:27.465Z",
"updatedon": "2024-07-12T09:12:27.465Z",
"buyonlinelink": null,
"producturl": "http://WWW.APPLIEDTECHNOSYSTEM.IN/products/insitu-zirconia-based-oxygen-analyzer/75",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": "",
"category": "OXYGEN ANALYZER",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": "",
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "5ba33018375ef300013f555a",
"fptag": "APPLIEDTECHNOSYSTEMS",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Dust Particulate Monitor",
"description": "Dust Monitor :\nWe are instrumental in providing our clients a comprehensive range of Dust Particulate Monitor. The offered monitor is manufactured by our experts in compliance with industry quality standards. This monitor is a device that is mounted in the discharge stack of a dust collector and continuously monitors the amount of particulate discharge. Our provided monitor is manufactured using the advanced technology, innovative machines and the finest grade raw material. Moreover, the entire array is tested on various stringent parameters to ensure its durability and quality.\n\nFeatures:\n\nCompact design\nLong service life\nLow maintenance cost\n\nOther Details:\n \n\nAdvanced detector for dust emissions and process flow applications\nEasily selectable alarm threshold level and time delay\nTwo independent SPDT relay contacts for alarm indications with selectable fail-safe mode\nIndustrially hardened, noise resistant design; can operate on an ESP and other challenging applications\nSuitable for all particulates - accurate sensing method\nvirtually maintenance-free - low cost of ownership\nSuitable for virtually all dust collectors\nData Logger with RS232/485 and USB Computer Interface\nWeb based data Transfer through GSM/GPRS technology\n\n\nSpecification:\nRange\t0-1000 Mg/M3\nSensor\tBase Systems Style\nIntegral\nRemote\nRemote Sensor Enclosure:\tCost Aluminum, Electrostatically powder coating\nProbe Material:\t316 Stainless Steel (Slandered) other materials available\nInsulator material:\tExtended High Performance (PFA) Temperature up to 250 C Ceramic (High temperature up to 550 Deg C )\nElectronics\t18 - 32 V DC () at the unit\n230V AC (Controller)\nOutput:\t4-20mA & SPDT Relay\nProbe Insertion length:\t3\" to 36\" ( 7.6 Cm to 91.4 Cm)\nInstallation\tWeld the supplied fitting into the pipe or Duct and insert Sensor\nSensor Mounting\tFlanged\n1/2\" Male NPT\nQuick release",
"price": 155500.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 7,
"_keywords": null,
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 57,
"imageuri": "https://productimages.withfloats.com/actual/5c11f28ce880e00001d66dc4.jpg",
"tileimageuri": "https://productimages.withfloats.com/actual/5c11f28ce880e00001d66dc4.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2018-09-20T05:28:56.066Z",
"updatedon": "2018-12-13T05:47:56Z",
"buyonlinelink": null,
"producturl": "http://WWW.APPLIEDTECHNOSYSTEM.IN/products/dust-particulate-monitor/57",
"availableunits": -1.0,
"iscodavailable": true,
"isprepaidonlineavailable": false,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "Stack Monitoring System",
"tags": [
"Stack Monitoring System",
"Dust Particulate Monitor",
"Continuous Stack Monitoring System",
"Dust Monitor",
"Stack Monitor"
],
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": null,
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": null,
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "5b85124b3dff7a05c131a33e",
"fptag": "APPLIEDTECHNOSYSTEMS",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Dew Point Transmitter",
"description": "Since our inception, we are instrumental in offering premium quality Dew Point Transmitter. This transmitter is designed as compact, simple and reliable instruments, which will continually monitor air dryer performance, compressed air quality and dry gas moisture, from ambient dew point levels to as low as -110ºC to 20ºC. Besides being manufactured from best-grade raw-material and advanced technology, the offered transmitter is inspected properly by our deft professionals. Owing to features like high efficiency and sturdiness, the offered transmitter is exceptionally valued by our precious clients. The offered transmitter is available with us in various sizes and other related specifications at affordable price.\n\nFeatures:\n\n Smooth performance\n Precisely design\n Long service life \n\nOther Details:\n\n Thin Film Capacitive Sensor Technology\n Multiple Housing Configurations\n Very Low Drift\n Long Sensor Life\n Robust Reliably Construction for Industrial Applications\n Samples Pressure Upto 12 Kg/C2M\n Inbuilt Thin film Capacitive sensor\n\n\nApplication:\n\n Monitoring Control of Air Dryers\n Plastic Dryers\n Natural Gas Processing, Transportation Distribution\n Glove Boxes\n Welding Gases",
"price": 65500.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 7,
"_keywords": [
"precious clients",
"Long service life",
"deft professionals",
"Monitoring Control",
"reliable instruments",
"air dryer performance",
"Natural Gas Processing",
"related specifications",
"ambient dew point levels",
"Samples Pressure Upto 12",
"Thin Film Capacitive Sensor",
"Inbuilt Thin film Capacitive",
"Robust Reliably Construction",
"offering premium quality Dew Point Transmitter"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 52,
"imageuri": "https://productimages.withfloats.com/actual/5c11f46ce3760b00011797da.jpg",
"tileimageuri": "https://productimages.withfloats.com/actual/5c11f46ce3760b00011797da.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2018-08-28T09:13:47.925Z",
"updatedon": "2018-12-13T05:55:56Z",
"buyonlinelink": null,
"producturl": "http://WWW.APPLIEDTECHNOSYSTEM.IN/products/dew-point-transmitter/52",
"availableunits": -1.0,
"iscodavailable": true,
"isprepaidonlineavailable": false,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "Dew Ponit Transmiter",
"tags": [
"Dew Ponit Transmiter",
"Moisture Transmitter"
],
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": null,
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": null,
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "5b850ef4a47c690556e36962",
"fptag": "APPLIEDTECHNOSYSTEMS",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Handheld Dust Monitor",
"description": "We have gained a remarkable position in the industry by offering a qualitative assortment of Handheld Dust Monitor that is used to monitor the suspended Particulate concentration in the air. The offered monitor is manufactured employing high-end technology and well-tested components in observance to industry defined guidelines. Apart from this, the entire range is scrupulously tested under the strict inspection of our quality controllers. This range can be availed from us in various specifications at market leading prices.\n\nFeatures:\n\n•Long service life\n•Precisely design\n•Require less maintenance\nOther Details:\n\n•Sampling dust and particulate matter is important as dust and particulate matter can affect the health of humans, as well as the natural environment.\n•Dust and particulate matter can cause respiratory problems when breathed in by humans. Dust and particulates above 10 micrometer (PM10) are filtered and generally do not enter the lungs.\n•Dust and particulate matter that is smaller than 10 micrometers (PM10, PM2.5, PM1.0) can enter into the Alveoli where gas exchange occurs.\n•This PM2.5 is more dangerous as it can affect the exchange of gases within the lungs and even penetrate the lung into the blood stream and cause other health issues.\n•PM10 , PM2.5 and PM1.0 are the normal sampling standards found throughout the world, they represent the particulate pollution that effects human health and thus sampling them provides an accurate insight into how dust and particulate matter effect human health.\n•Handheld/Portable PM Monitor is used to monitor the suspended Particulate concentration in the air with measuring range 0.001mg/M3 to 10 mg/M3.\n•It adopts optical scattering technique. This type of Product has many advantages, such as fast detection speed, high accuracy, light and small, easy operation, measuring and displaying of 3 channels at the same time.\n•It adopts the method of automatic measurement, improving the work efficiency effectively.\n\n\nSpecification :\n\nMeasuring principle Optical scattering technology\n\nLight Source Laser Diode\n\nDetection Range 0.001 – 10mg/m3\n\nDisplay LCD\n\nSize Channel PM10, PM2.5, PM1.0\n\nFlow Rate 2.83L/min (Imported Pump)\n\nSample Time 0-9999s Selectable\n\nZero Count\n\nPrinter External thermal printer\n\nData Storage 1000\n\nOperating Time 5 hours\n\nOutside Dim 130*220*45(Wide*High*Deep)\n\nWeight 0.6kg\n\nTemperature 15degree Celsius\n\nHumidity\n\nAtmosphere Pressure 86-106Kpa",
"price": 135500.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 7,
"_keywords": [
"accurate insight",
"strict inspection",
"principle Optical",
"quality controllers",
"remarkable position",
"effects human health",
"Handheld Dust Monitor",
"particulate pollution",
"automatic measurement",
"various specifications",
"qualitative assortment",
"Particulate concentration",
"normal sampling standards",
"cause respiratory problems",
"particulate matter effect human"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 49,
"imageuri": "https://productimages.withfloats.com/actual/5c11f416cf760c0001e037d1.jpg",
"tileimageuri": "https://productimages.withfloats.com/actual/5c11f416cf760c0001e037d1.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2018-08-28T08:59:32.218Z",
"updatedon": "2018-12-13T05:54:30Z",
"buyonlinelink": null,
"producturl": "http://WWW.APPLIEDTECHNOSYSTEM.IN/products/handheld-dust-monitor/49",
"availableunits": -1.0,
"iscodavailable": true,
"isprepaidonlineavailable": false,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "PM Monitor",
"tags": [
"PM Monitor",
"Indoor Air Quality Monitor",
"Handhel Dust Monitor",
"Dust Monitor",
"Portable Dust Monitor"
],
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": null,
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": null,
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "5b6b3ac6d657ba0548535132",
"fptag": "APPLIEDTECHNOSYSTEMS",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Tri Gas Analyser Model ATS 204A - Manufacturers in Mumbai",
"description": "he Hydrogen Purity and Purge Gas analyzer have been design especially for cylindrical and power station to check the Hydrogen Purity. The Analyzer is supplied in robust and reliable construction having Li-IONE rechargeable battery with 6 Hour of continuous operation. The integral Pump, Needle valve and Flow meter are used to control the sample through the analyzer during the monitoring of alternator gases.\n\nSpecifications:\n\n•Principle: Thermal Conductivity and NDIR (Non dispersive Infrared )\n•Range:Tri Gas Range 0-100% CO2 in Air , 0-100% H2 In CO2 and 90-100% H2 in Air %V/V\n\n•Resolution: 0.1 Unit or 1 Unit (Application based)\n•Sampling Method: Auto Suction or Direct Plug In\n•Display: 128 X 64 Graphics LCD\n•Alarm; Two Levels Low High, Visual and Audible\n•Power Source: Built in Lithium Rechargeable battery\n•Accuracy: /2%\n•Response Time: Data Storage: 5000 or 10000\n•Computer Interface: RS 232, USB, RS485\n•Sensor Life: 4-5 Years\n•Operating Time: 6 – 8 hours\n•\n\n\n\nEnvironmental:\n\n•Temperature:-15degree Celsius Humidity :< 85%RH Atmosphere Pressure: 86- 106Kpa\n\n•Housing: High Impact Plastic\n•Dimension in mm: 200 (W) X 120 (H) X 185(D)\n•Weight: 1.5 KG\n•Warranty: One Year",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 7,
"_keywords": [
"KG",
"mm",
"CO2",
"USB",
"NDIR",
"Unit",
"•Range",
"Method",
"sample",
"design",
"Audible",
"•Display",
"Air %V/V",
"•Accuracy",
"monitoring",
"•Principle",
"Flow meter",
"Application",
"•Resolution",
"Direct Plug",
"Data Storage",
"•Sensor Life",
"Graphics LCD",
"Needle valve",
"Auto Suction",
"Manufacturers",
"•Power Source",
"integral Pump",
"Tri Gas Range",
"power station",
"•Response Time",
"Model ATS 204A",
"Specifications",
"Levels Low High",
"Tri Gas Analyser",
"alternator gases",
"Purge Gas analyzer",
"High Impact Plastic",
"•Computer Interface",
"continuous operation",
"Thermal Conductivity",
"reliable construction",
"RH Atmosphere Pressure",
"Non dispersive Infrared",
"Mumbai-he Hydrogen Purity",
"-15degree Celsius Humidity",
"Lithium Rechargeable battery",
"Li-IONE rechargeable battery"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 22,
"imageuri": "https://productimages.withfloats.com/actual/594e2353a6122d0bf4a70cd4.jpg",
"tileimageuri": "https://productimages.withfloats.com/actual/594e2353a6122d0bf4a70cd4.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2017-06-24T08:31:15.394Z",
"updatedon": "2018-08-08T18:47:34Z",
"buyonlinelink": null,
"producturl": "http://WWW.APPLIEDTECHNOSYSTEM.IN/products/tri-gas-analyser-model-ats-204a-manufacturers-in-mumbai/22",
"availableunits": -1.0,
"iscodavailable": true,
"isprepaidonlineavailable": false,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": null,
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": null,
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "5b6b3ac6d657ba05485350fc",
"fptag": "APPLIEDTECHNOSYSTEMS",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Hydrogen Purity Analyser ",
"description": "Hydrogen Purity Analyser The Hydrogen Purity and Purge Gas analyzer have been design especially for cylindrical and power station to check the Hydrogen Purity. The Analyzer is supplied in robust and reliable construction having Li-IONE rechargeable battery with 6 Hour of continuous operation. The integral Pump, Needle valve and Flow meter are used to control the sample through the analyzer during the monitoring of alternator gases. Features: Simple Low Cost maintenance Microcontroller based embedded intelligent instruments H2 gas Range : 85-100%V/V Optional Tri Gas Range 0-100% CO2 in Air , 0-100% H2 In CO2 and 90-100%H2 in Air User friendly Interface Direct Plug In Or Auto Suction Sampling 128 x 64 Graphics LCD Display USB/RS 232 Computer Interface Long Life Rechargeable Li-IONE Battery Specification: Principle Thermal Conductivity and NDIR (Non dispersive Infrared ) Range %V/V Resolution 0.1 Unit or 1 Unit (Application based) Sampling Method Auto Suction or Direct Plug In Display 128 X 64 Graphics LCD Alarm Two Levels Low & High Visual and Audible Power Source Built in Lithium Rechargeable battery Accuracy /2% Response Time Data Storage 5000 or 10000 Computer Interface RS 232, USB, RS485 Sensor Life 4-5 Years Operating Time 6 8 hours Environmental Temperature 15degree Celsius Humidity Atmosphere Pressure 86- 106Kpa Housing High Impact Plastic Dimension in mm 200 (W) X 120 (H) X 185(D) Weight 1.5 KG Warranty One Year Application: Hydrogen Cooled Alternators & Turbine Hydrogen",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 7,
"_keywords": [
"mm",
"Air",
"CO2",
"NDIR",
"Unit",
"User",
"design",
"Simple",
"sample",
"Features",
"Accuracy",
"Flow meter",
"Levels Low",
"Application",
"instruments",
"KG Warranty",
"High Visual",
"Interface RS",
"H2 gas Range",
"Needle valve",
"integral Pump",
"power station",
"Tri Gas Range",
"Turbine Hydrogen",
"alternator gases",
"RS485 Sensor Life",
"Response Time Data",
"Graphics LCD Alarm",
"Purge Gas analyzer",
"Method Auto Suction",
"106Kpa Housing High",
"Audible Power Source",
"Graphics LCD Display",
"continuous operation",
"Interface Direct Plug",
"reliable construction",
"Auto Suction Sampling",
"Non dispersive Infrared",
"Impact Plastic Dimension",
"Environmental Temperature",
"-Hydrogen Purity Analyser",
"Hydrogen Cooled Alternators",
"Celsius Humidity Atmosphere",
"Lithium Rechargeable battery",
"Rechargeable Li-IONE Battery",
"Li-IONE rechargeable battery",
"Principle Thermal Conductivity",
"Cost maintenance Microcontroller"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 20,
"imageuri": "https://productimages.withfloats.com/actual/592816a500c63a0a945c4861.jpg",
"tileimageuri": "https://productimages.withfloats.com/actual/592816a500c63a0a945c4861.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2017-05-26T11:51:01.984Z",
"updatedon": "2018-08-08T18:47:34Z",
"buyonlinelink": null,
"producturl": "http://WWW.APPLIEDTECHNOSYSTEM.IN//hydrogen-purity-analyser-/20",
"availableunits": -1.0,
"iscodavailable": true,
"isprepaidonlineavailable": false,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": null,
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": null,
"gstslab": 0.0,
"isnotforsale": false
}
],
"hasmoreitems": false,
"isapirequest": false,
"totalresults": 27,
"query": null,
"floatingpoint": null
}