Preview

This is your website preview.

Currently it only shows your basic business info. Start adding relevant business details such as description, images and products or services to gain your customers attention by using Boost 360 android app / iOS App / web portal.

APPLIEDTECHNOSYSTEMS 590481e09e768b0560d08878 Products https://www.appliedtechnosystem.in
{ "products": [ { "_id": "66b1b4808cf0f2194c135b73", "fptag": "APPLIEDTECHNOSYSTEMS", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": " Online Stack Emission Monitor System with dual display", "description": "Model ATS -208A Gas with dual displayAnalyzer continuously monitors the concentration of gasesranging from 100%V/V down to PPM level. Feature includes a duel wavelengthsensor, Remote Sampling, Graphics LCD Display, adjustable level relay output foralarm and 4-20mAoutput for control purpose and minimal maintenance.Special gas sample Conditioning systems are used to clean and dry the gas samplefor accurate and High performance operation. An Internal Pump draw gas sampleinto the sensor through a dust particle filter from an intake which can be located atdistance up to 40 meter form the monitor.The Sensor and Electronic component are housed in tough aluminium housingFor hazardous area applicationsthe sensor may be mounted remotely in thehazardous areaand safely connected via anzener barrier to the electronics unit inthe safe area. Alternatively the electronicsunit can be supplied in an Explosion proofenclosure.\n\nspacification\n\n· Accuracy : +/- 2%.\n\n· Display : High quality 320 x 264 Graphics LCD\n\n· Sampling : Auto Suction Sampling through Inbuilt Pump\n\n· Digital Output : RS-485\n\n· Zero Calibration: Automatic at instrument start up with fresh air sample.\n\n· Power Supply : Power Supply 230V AC\n\n· Measuring Principle : Dynamic Detection Principle DDP\n\n· Analogue Output : 4-20mA\n\n· Path Length : 0.25 to 10 meter", "price": 0.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 0, "_keywords": [ "208A Gas", "Model ATS", "safe area", "PPM level", "The Sensor", "LCD Display", "Path Length", "to 40 meter", "Auto Suction", "Inbuilt Pump", "High quality", "gas samplefor", "gas sampleinto", "Digital Output", "Remote Sampling", "anzener barrier", "control purpose", "Analogue Output", "264 Graphics LCD", "0.25 to 10 meter", "Zero Calibration", "electronics unit", "An Internal Pump", "fresh air sample", "minimal maintenance", "Measuring Principle", "thehazardous areaand", "Electronic component", "dual displayAnalyzer", "dust particle filter", "Power Supply 230V AC", "duel wavelengthsensor", "Explosion proofenclosure", "High performance operation", "tough aluminium housingFor", "hazardous area applicationsthe", "Dynamic Detection Principle DDP", "Online Stack Emission Monitor System", "adjustable level relay output foralarm", "Special gas sample Conditioning systems" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 82, "imageuri": "https://bizimages.withfloats.com/actual/7ab5ae6b53364f3f925f87f2a9faa88d.jpg", "tileimageuri": "https://bizimages.withfloats.com/actual/7ab5ae6b53364f3f925f87f2a9faa88d.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2024-08-06T05:28:32.689Z", "updatedon": "2024-08-06T05:28:32.689Z", "buyonlinelink": null, "producturl": "http://WWW.APPLIEDTECHNOSYSTEM.IN/products/-online-stack-emission-monitor-system-with-dual-display/82", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": true, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": "", "category": "Stack Monitoring System", "tags": null, "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": "", "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": "", "gstslab": 0.0, "isnotforsale": false }, { "_id": "6690f37b62369a1a08b058c3", "fptag": "APPLIEDTECHNOSYSTEMS", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "INSITU ZIRCONIA BASED OXYGEN ANALYZER", "description": "FEATURES \n1)Zirconia oxide sensor, giving real measurement of excess oxygen\n2. Long life zirconium Sensor\n3. Reliable out put , adaptable to close loop control\n4. Easy to Operate\n5. Wide Measurement Range 1PPM to 96%\n6. Easy installation, all hardware supplied with the system.\n7. Completely field repairable.\n8. Digital electronics package in IP 65 housing.\n9. Explosion-proof housing available as option.\n10. Auto & manual calibration facility for zirconium sensor.\n11. Micro controller based digital systems with user friendly\nAPPLICATIONS ·\nGas Manufacturing & Testing Petrochemicals & Chemical Industry ·\n· Exhaust Gas Analysis\n· Food Packing Factory\n· Monitor Vehicle Emission\n· Low oxygen Mesurment at industrial Process ·\n· Steel Plant Air Quality Monitoring, Oxygen Monitoring\n· Laboratories & Institutions\n· Metal Processing Plant\n· Petrochemical & Chemical Industries\n· Pharmaceutical Industries \nTECHNICAL SPECIFICATIONS\nPower supply :-24V ±10% Limited Power Supply\nPower consumption :-700mA maximum @ 24V\nAnalog outputs :-Single or Dual 420mA\nOutput ranges (oxygen) :-0— 25% vol.O2\nOutput ranges (pressure):- 750 — 1260mbar absolute\nRelays (SPST, N/O as std.):- 1 x system alarm (SPST)\n 1 x user configurable O set point alarm\nDigital communications :- RS485 Modbus RTU protocol\nDisplay :-16 character, 2 - line, backlit\n\nOPERATING CONDITIONS\nAmbient temperature:- 20 to +55°C (4 to +131°F)\nAmbient relative humidity :-95% RH\nGas composition Combustion gas from natural gas, biogas or oil\nSample gas temperature:- +700°C (1292°F)\nSample gas flow rate :-4m/s minimum recommended\nCompensated pressure :-750 — 1260mbar absolute", "price": 230000.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 0, "_keywords": [ "5% RH", "25% vol", "65 housing", "point alarm", "natural gas", "user friendly", "excess oxygen", "Analog outputs", "Combustion gas", "digital systems", "Gas composition", "Micro controller", "real measurement", "1 x system alarm", "O2 Output ranges", "Chemical Industry", "Easy installation", "Gas Manufacturing", "Power consumption", "Oxygen Monitoring", "industrial Process", "close loop control", "Chemical Industries", "Ambient temperature", "Compensated pressure", "OPERATING CONDITIONS", "Exhaust Gas Analysis", "Low oxygen Mesurment", "Food Packing Factory", "Sample gas flow rate", "1 x user configurable", "Digital communications", "Wide Measurement Range", "Sample gas temperature", "Metal Processing Plant", "Explosion-proof housing", "1)Zirconia oxide sensor", "1260mbar absolute Relays", "Monitor Vehicle Emission", "Dual 420mA Output ranges", "Pharmaceutical Industries", "Ambient relative humidity", "Long life zirconium Sensor", "Digital electronics package", "manual calibration facility", "RS485 Modbus RTU protocol Display", "Steel Plant Air Quality Monitoring", "TECHNICAL SPECIFICATIONS Power supply", "INSITU ZIRCONIA BASED OXYGEN ANALYZER" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 75, "imageuri": "https://bizimages.withfloats.com/actual/895d17c6f4da464e8654f534e6a43f67.jpg", "tileimageuri": "https://bizimages.withfloats.com/actual/895d17c6f4da464e8654f534e6a43f67.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2024-07-12T09:12:27.465Z", "updatedon": "2024-07-12T09:12:27.465Z", "buyonlinelink": null, "producturl": "http://WWW.APPLIEDTECHNOSYSTEM.IN/products/insitu-zirconia-based-oxygen-analyzer/75", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": true, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": "", "category": "OXYGEN ANALYZER", "tags": null, "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": "", "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": "", "gstslab": 0.0, "isnotforsale": false }, { "_id": "5ba3344e2618910001e11f09", "fptag": "APPLIEDTECHNOSYSTEMS", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "Digital Online Dew point Analyzer", "description": "Digital Online Dew point Analyzer - Model ATS 303D.\nIdeal for precise monitoring of moisture or dew point in air or gas output from dryers system or in process. Continous monitoring of dew point results in reduced maintance costs and downtime caused by separated moisture, The main cause of corrosion in pneumatic systems. the analyzer usesa highly accurate capacitive integrated thin film water vapor sensor,and is an economic alternative to the chilled-mirror dew point type meters. It utilizes microprocessor based circuits to give a direct read out in dew point or other units and other units corresponding to sensor output based on psychometric equations. To achieve higher accuracies it uses temperature compensation over complete operational range.The insturment is contained in a high impact plastic housing.\n\nApplication: Compressed air, Industrial process control,Drying system, Protection systems,Glove box, Turbines, HVAC & Breathing air\n\nSpecification:\nApplication: Compressed Air/ Gas\n\n· Range: -60 to +30 Deg C\n\n· Moisture : 0-23000 PPM\n\n· Accuracy : 0-30 deg c +/-1%.\n\n-60 to 0 Deg C +/- 1.5%\n\n· Display : High quality Graphics LCD (128x 64)\n\n· Sampling : Direct Plug In\n\n· Power Supply : Rechargeable Ni-cad Battery Pack with Charger.\n\n· Response Time: 30 seconds at 95% variation.\n\n· Operating Temperature: -5 to 55deg.C\n\n· Data Logger with computer interface\n\n", "price": 110500.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 7, "_keywords": null, "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 61, "imageuri": "https://productimages.withfloats.com/actual/5c11f3311b1bb60001089d6f.jpg", "tileimageuri": "https://productimages.withfloats.com/actual/5c11f3311b1bb60001089d6f.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2018-09-20T05:46:54.751Z", "updatedon": "2018-12-13T05:50:41Z", "buyonlinelink": null, "producturl": "http://WWW.APPLIEDTECHNOSYSTEM.IN/products/digital-online-dew-point-analyzer/61", "availableunits": -1.0, "iscodavailable": true, "isprepaidonlineavailable": false, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": null, "category": "Online Dew Point Analyzer", "tags": [ "Online Dew Point Analyzer", "Fixed Dew Point Analyzer", "Dew Point Monitor" ], "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": null, "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": null, "gstslab": 0.0, "isnotforsale": false }, { "_id": "5b72675f098ce10520d5f973", "fptag": "APPLIEDTECHNOSYSTEMS", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "Online SOX Gas Analyser", "description": "Applied has years of experience and knowledge in this domain, we are engaged in offering an excellent range of Online SOx Gas Analyser. This analyzer is thoroughly manufactured at our advanced manufacturing unit using the best quality raw material and innovative technology in observance with defined quality standards. This analyzer is used to clean and dry the gas sample for accurate and high performance operation. Being a quality-oriented organization, we assure our clients that this analyzer is excellent on counts of durability and quality.\n\nFeatures:\n\n Compact design\n Easy to operate\n Superior performance\n\n\nOther Details:\n\n\n Model ATS- 208A Emission Analyzer continuously monitors the concentration of SOX ,SO2 PPM level. Feature includes a duel wavelength sensor, Remote Sampling, Graphics LCD Display, adjustable level relay output for alarm and 4-20mA output for control purpose and minimal maintenance.\n Special gas sample Conditioning systems are used to clean and dry the gas sample for accurate and High performance operation. An Internal Pump draw gas sample into the sensor through a dust particle filter from an intake which can be located at distance up to 40 meter form the monitor.\n The Sensor and Electronic component are housed in tough aluminium housing\n Microcontroller based embedded intelligent instruments\n Continuous Monitoring of SO2 & SOX\n Duel wavelength Infra red sensor for Long terms accuracy and stability\n Long Life Electrochemical sensor\n Six Gas Analysis in Single Analyser\n Multi Parameter Single 320 X 240 Graphics LCD Display\n Self diagnostic & Self integrity check\n RS 232/RS 485 and USB Computer Interface\n Excellent low level capability for NOX and SO2 Measurement\n For most of the application sample gas is cooled and dried inside the sampling conditioning systems to avoid the Heated Sample Line.\n Analog 4-20mA output for each gas\n Software solutions for Gas Analysis\n Web Based Real time data transfer with GSM/GPRS Technology", "price": 325500.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 7, "_keywords": [ "Graphics LCD Display", "quality raw material", "application sample gas", "duel wavelength sensor", "Online SOX Gas Analyser", "Real time data transfer", "Long Life Electrochemical", "High performance operation", "advanced manufacturing unit", "Internal Pump draw gas sample", "adjustable level relay output", "Excellent low level capability", "Duel wavelength Infra red sensor", "Special gas sample Conditioning systems", "Multi Parameter Single 320 X 240 Graphics LCD" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 40, "imageuri": "https://productimages.withfloats.com/actual/5b850082f047bd0543cb6c28.jpg", "tileimageuri": "https://productimages.withfloats.com/actual/5b850082f047bd0543cb6c28.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2018-08-14T05:23:43.374Z", "updatedon": "2018-08-28T07:57:54Z", "buyonlinelink": null, "producturl": "http://WWW.APPLIEDTECHNOSYSTEM.IN/products/online-sox-gas-analyser/40", "availableunits": -1.0, "iscodavailable": true, "isprepaidonlineavailable": false, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": null, "category": "", "tags": null, "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": null, "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": null, "gstslab": 0.0, "isnotforsale": false }, { "_id": "5b7264446d82d50505b27998", "fptag": "APPLIEDTECHNOSYSTEMS", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "Oxygen Analyser", "description": "Oxygen Analyzer Model ATS-208A\n\nFeatures\n\n· Micro controller based embedded intelligent instruments\n· Long Life Electrochemical sensor\n· Proven technology from gas analyser experts\n\n• ppm or % O2 levels\n\n• Hazardous area options\n\n• Choice of cells for different applications\n\n• Remote or integral sensor\n\n• Choice of sample systems\n\nApplications\n\n• Nitrogen generators\n\n• Inert gas systems\n\n• Air separation\n\n• Furnace atmospheres\n\n• Biogas\n\n• Gloveboxes\n\n• Gasification\n\n• Packaging\n\nThe ATS -208A oxygen analysers have numerous applications in processes requiring the precise measurement of oxygen level. In ppm or % levels, safe areas or hazardous ones, in various process conditions and in differing backgrounds there is a ATS – 208A configuration right for your needs. Options include a choice of outputs, AC or DC versions, alternative oxygen cells or sample conditioning.\n\nOxygen is measured in a wide variety of processes, to confirm its presence or absence. The most common application however is measuring oxygen as an 'impurity' in other gases, e.g. nitrogen generators. Oxygen is required in aerobic processes and also in situations that require user intervention, e.g. to ensure that it is safe to enter a chamber for maintenance work. Some processes will only run efficiently in the absence of oxygen, e.g. furnace atmospheres; others just require a low level of oxygen for safety reasons, e.g. inert gas blanketing.\n\nDifferent electrochemical cells are available to suit the application. The standard A cell has a broad range from high ppm to 50% oxygen. The ‘B’ cell is designed for accuracy at low ppm levels; it will also work at % levels (with a shorter lifetime). The ‘C’ cell is designed for use in % levels of oxygen in the presence of mildly acidic gases, e.g. carbon dioxide, while the ‘D’ cell is perfect for low ppm oxygen applications where hydrogen is present. Applied will be pleased to advise on which cell is most suitable for an application.\n\nA choice of configuration is available. The most convenient and economic is a standard analyser with the cell mounted on the rear. Alternatively, there is remote sensor housing complete with flowmeter and valve. Where cable lengths and/or hazardous area conditions are an issue, the transmitter can be located in the sensor housing\n\nDifferent sample conditioning systems are available, standard or bespoke, according to the process conditions. Filters, pumps and regulators can all be incorporated to deliver the sample in the correct condition. Bypass flow systems enable longer distances from process to analyser to be achieved. Applied engineers are ready to recommend the right system for you on receipt of the full gas stream specification.\n\nFor hazardous area applications the sensor may be mounted remotely in the hazardous area and safely connected via an zener barrier to the electronics unit in the safe area. Alternatively the electronics unit can be supplied in an Explosion proof enclosure.", "price": 125500.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 0, "_keywords": [ "oxygen cells", "low ppm levels", "oxygen analysers", "numerous applications", "electrochemical cells", "Oxygen Analyzer Model", "sensor housing complete", "208A configuration right", "hazardous area conditions", "Explosion proof enclosure", "Long Life Electrochemical", "various process conditions", "Bypass flow systems enable", "low ppm oxygen applications", "hazardous area applications" ], "isarchived": false, "isavailable": false, "applicationid": null, "productindex": 39, "imageuri": "https://productimages.withfloats.com/actual/5c11f4c337862000011ac467.jpg", "tileimageuri": "https://productimages.withfloats.com/actual/5c11f4c337862000011ac467.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2018-08-14T05:10:28.232Z", "updatedon": "2018-12-13T05:57:22Z", "buyonlinelink": null, "producturl": "http://WWW.APPLIEDTECHNOSYSTEM.IN/products/oxygen-analyser/39", "availableunits": -1.0, "iscodavailable": true, "isprepaidonlineavailable": false, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": null, "category": "", "tags": null, "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": null, "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": null, "gstslab": 0.0, "isnotforsale": false }, { "_id": "5b6ea828b5dfa70508cd4124", "fptag": "APPLIEDTECHNOSYSTEMS", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "Online Stack Monitoring Systems", "description": "\nApplied Techno Systems offer comprehensive range of stack gas Analyzer Portable and Continuous for the analysis of stack/flue gases in exhaust, boiler and combustion process. Model ATS- 206A Flue gas Analyzer measure the flue gases after placing its probe into stack or appliance exhaust and see the concentration of Oxygen (O2), Carbon Monoxide (CO) Carbon Dioxide (CO2). Efficient combustion also reduces emission of pollutants such as nitric oxide (NO), nitrogen dioxide (NO2), sulphur dioxide (SO2), and particulate matter. A gas analyzer will also help measure various gas pollutants in the exhaust for environmental reasons.\n\n· Microcontroller based embedded intelligent instruments\n\n· Continuous Monitoring of CO2 ,CH4, CO, O2, SO2, NOX (NO NO2), H2, H2S, N2\n\n· Duel wavelength Infra red sensor for Long terms accuracy and stability\n\n· Long Life Electrochemical sensor\n\n· Six Gas Analysis in Single Analyser\n\n· Multi Parameter Single 320 X 240 Graphics LCD Display\n\n· Self diagnostic & Self integrity check\n\n· RS 232/RS 485 and USB Computer Interface\n\n· Excellent low level capability for NOX and SO2 Measurement\n\n· For most of the application sample gas is cooled and dried inside the sampling conditioning systems to avoid the Heated Sample Line.\n\n· Analog 4-20mA output for each gas\n\nModel ATS- 208A Emission Analyzer continuously monitors the concentration of gases ranging from 100%V/V down to PPM level. Feature includes a duel wavelength sensor, Remote Sampling, Graphics LCD Display, adjustable level relay output for alarm and 4-20mA output for control purpose and minimal maintenance.\n\nSpecial gas sample Conditioning systems are used to clean and dry the gas sample for accurate and High performance operation. An Internal Pump draw gas sample into the sensor through a dust particle filter from an intake which can be located at distance up to 40 meter form the monitor.\n\nThe Sensor and Electronic component are housed in tough aluminium housing\n\nSpecifications:\n\nPrinciple: Electrochemical, TCD (Thermal Conductivity) , NDIR (Non Dispersive Infrared ), Zirconium and Paramagnetic\n\nRange: %V/V, % LEL, PPM, Mg/M3\n\nResolution: 0.1 Unit or 1 Unit (Application based)\n\nSampling Method: Auto Suction\n\nDisplay: 320 X 264 Graphic LCD", "price": 325100.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 0, "_keywords": [ "Graphics LCD Display", "320 X 264 Graphic LCD", "application sample gas", "duel wavelength sensor", "208A Emission Analyzer", "Long Life Electrochemical", "High performance operation", "stack gas Analyzer Portable", "Internal Pump draw gas sample", "adjustable level relay output", "206A Flue gas Analyzer measure", "measure various gas pollutants", "Excellent low level capability", "gas sample Conditioning systems", "Multi Parameter Single 320 X 240 Graphics LCD" ], "isarchived": false, "isavailable": false, "applicationid": null, "productindex": 38, "imageuri": "https://productimages.withfloats.com/actual/5b8500c6016722053c706450.jpg", "tileimageuri": "https://productimages.withfloats.com/actual/5b8500c6016722053c706450.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2018-08-11T09:11:04.461Z", "updatedon": "2018-08-28T07:59:01Z", "buyonlinelink": null, "producturl": "http://WWW.APPLIEDTECHNOSYSTEM.IN/products/online-stack-monitoring-systems/38", "availableunits": -1.0, "iscodavailable": true, "isprepaidonlineavailable": false, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": null, "category": "stack monitoring system", "tags": [ "stack monitoring system", "gas analyzer", "continuous emission monitoring systems" ], "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": null, "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": null, "gstslab": 0.0, "isnotforsale": false }, { "_id": "5b6d4da1a65fa004f7667f39", "fptag": "APPLIEDTECHNOSYSTEMS", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "HF Gas Analyser", "description": "Continuous HF Analyzer Model ATS-208A For SSP (Single Super Phospahate) Plant\n\n. Features\n\n· Microcontroller based embedded intelligent instruments\n\n· Continuous Monitoring of HF\nLong Life Electrochemical sensor\nMulti Parameter Single 320 X 240 Graphics LCD Display\n\n· Self diagnostic & Self integrity check\n\n· RS 232/RS 485 and USB Computer Interface\n\n· For most of the application sample gas is cooled and dried inside the sampling conditioning systems to avoid the Heated Sample Line.\n\n· Analog 4-20mA output for each gas\n\n· Software solutions for Gas Analysis\n\n· Web Based Real time data transfer\n\n· Model ATS- 208A Emission Analyzer continuously monitors the concentration of HF ranging from PPM level. Feature includes a duel wavelength sensor, Remote Sampling, Graphics LCD Display, adjustable level relay output for alarm and 4-20mA output for control purpose and minimal maintenance.\n\nSpecial gas sample Conditioning systems are used to clean and dry the gas sample for accurate and High performance operation. An Internal Pump draw gas sample into the sensor through a dust particle filter from an intake which can be located at distance up to 40 meter form the monitor.\n\nThe Sensor and Electronic component are housed in tough aluminium housing\n\nSpecifications:\n\nPrinciple: Electrochemical,\n\nRange: 0-10/50PPM\n\nResolution: 0.1 Unit or 1 Unit (Application based)\n\nSampling Method: Auto Suction\n\nDisplay: 320 X 264 Graphic LCD\n\nAlarm; Relay Contact NO NC\n\nAnolog Out Put: 4-20mA\n\nDigital Out Put : RS 232, RS 485 and Modbus Comminication Protocol\n\nPower Source:230VAC\n\nAccuracy: /2%\n\nResponse Time:\n\nSensor Life: 2-3 Years\n\nDimension in mm: 430 (W) X 150(H) X 250(D)", "price": 440500.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 0, "_keywords": [ "320 X 264 Graphic", "Graphics LCD Display", "Life Electrochemical", "dust particle filter", "Continuous Monitoring", "application sample gas", "208A Emission Analyzer", "duel wavelength sensor", "Single Super Phospahate", "High performance operation", "Continuous HF Analyzer Model", "Internal Pump draw gas sample", "adjustable level relay output", "gas sample Conditioning systems", "Parameter Single 320 X 240 Graphics LCD" ], "isarchived": false, "isavailable": false, "applicationid": null, "productindex": 35, "imageuri": "https://productimages.withfloats.com/actual/5b8501bc3cb3d6054472ba16.jpg", "tileimageuri": "https://productimages.withfloats.com/actual/5b8501bc3cb3d6054472ba16.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2018-08-10T08:32:33.881Z", "updatedon": "2018-08-28T08:03:08Z", "buyonlinelink": null, "producturl": "http://WWW.APPLIEDTECHNOSYSTEM.IN//hf-gas-analyser/35", "availableunits": -1.0, "iscodavailable": true, "isprepaidonlineavailable": false, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": null, "category": "", "tags": null, "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": null, "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": null, "gstslab": 0.0, "isnotforsale": false }, { "_id": "5b6b3ac6d657ba05485351cb", "fptag": "APPLIEDTECHNOSYSTEMS", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "Ammonia Gas Analyser", "description": "Online Ammonia Gas Monitoring Systems MODEL ATS-208A\n\nModel ATS- 208A Ammonia Gas Analyzer continuously monitors the concentration of Ammonia in PPM and other gases ranging from 100%V/V down to PPM level. Feature includes a duel wavelength sensor, Remote Sampling, Graphics LCD Display, adjustable level relay output for alarm and 4-20mA output for control purpose and minimal maintenance.\n\n\nSpecial gas sample Conditioning systems are used to clean and dry the gas sample for accurate and High performance operation. An Internal Pump draw gas sample into the sensor through a dust particle filter from an intake which can be located at distance up to 40 meter form the monitor.\n\n\nThe Sensor and Electronic component are housed in tough aluminum housing\n\n\nApplications\n\n\n Metal heat Treatment\n Boiler Systems\n Cement & Lime Manufacturer\n Combustion Process\n Hydrogen Cooled Alternators & Turbine\n Gasification & Syngas\n Pulp & Paper\n Metal Heat Treatment Plant\n Laboratories & Institutions\n Flame Treatment Process & Chemical Industries\n Petrochemical & Pharmaceutical Industries\n\n\nFeatures\n\n Microcontroller based embedded intelligent instruments\n Continuous Monitoring of CO2 ,CH4, CO, O2, SO2, NOX (NO NO2), H2, H2S, N2\n Duel wavelength Infra red sensor for Long terms accuracy and stability\n Long Life Electro chemical sensor\n Six Gas Analysis in Single Analyzer\n Multi Parameter Single 320 X 240 Graphics LCD Display\n Self diagnostic & Self integrity check\n RS 232/RS 485 and USB Computer Interface\n Excellent low level capability for NOX and SO2 Measurement\n For most of the application sample gas is cooled and dried inside the sampling conditioning systems to avoid the Heated Sample Line.\n Analog 4-20mA output for each gas\n Software solutions for Gas Analysis\n Web Based Real time data transfer with GSM/GPRS Technology", "price": 155500.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 7, "_keywords": [ "Ammonia Gas Analyser", "application sample gas", "duel wavelength sensor", "Flame Treatment Process", "Real time data transfer", "208A Ammonia Gas Analyzer", "Long Life Electro chemical", "High performance operation", "Online Ammonia Gas Monitoring", "Internal Pump draw gas sample", "adjustable level relay output", "Excellent low level capability", "gas sample Conditioning systems", "Duel wavelength Infra red sensor", "Multi Parameter Single 320 X 240 Graphics LCD" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 32, "imageuri": "https://productimages.withfloats.com/actual/5b695e411527ef0508e32ff9.jpg", "tileimageuri": "https://productimages.withfloats.com/actual/5b695e411527ef0508e32ff9.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2018-08-07T08:54:25.233Z", "updatedon": "2018-08-08T18:47:34Z", "buyonlinelink": null, "producturl": "http://WWW.APPLIEDTECHNOSYSTEM.IN//ammonia-gas-analyser/32", "availableunits": -1.0, "iscodavailable": true, "isprepaidonlineavailable": false, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": null, "category": "Online Gas Monitoring Systems", "tags": [ "Online Gas Monitoring Systems", "Ammonia Gas Montiring System", "Continuous Gas Monitors" ], "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": null, "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": null, "gstslab": 0.0, "isnotforsale": false }, { "_id": "5b6b3ac6d657ba05485351a1", "fptag": "APPLIEDTECHNOSYSTEMS", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "SOX NOX Analyzer", "description": "Applied Techno Systems : The Pioneers Of Air Pollution & Stack Emission Monitoring systems In India (TUV Approved)The Applied Model ATS 208A Continuous Emission Monitoring System is designed to meet the needs of organizations requiring cost effective and reliable multiple gas analyzer solutions. The technology employed are all tried and tested to ensure the user experiences maximum reliability and accuracy.\n\n Microcontroller based embedded intelligent instruments\n Continuous Monitoring of CO2 ,CH4, CO, O2, SO2, NOX (NO+NO2), H2, H2S, N2\n Duel wavelength Infra red sensor for Long terms accuracy and stability\n Long Life Electrochemical sensor\n Six Gas Analysis in Single Analyser\n Multi Parameter Single 320 X 240 Graphics LCD Display\n Self diagnostic & Self integrity check\n RS 232/RS 485 and USB Computer Interface\n Excellent low level capability for NOX and SO2 Measurement\n For most of the application sample gas is cooled and dried inside the sampling conditioning systems to avoid the Heated Sample Line.\n Analog 4-20mA output for each gas\n Software solutions for Gas Analysis\n Web Based Real time data transfer with GSM/GPRS Technology\n Model ATS- 208A Emission Analyzer continuously monitors the concentration of gases ranging from 100%V/V down to PPM level. Feature includes a duel wavelength sensor, Remote Sampling, Graphics LCD Display, adjustable level relay output for alarm and 4-20mA output for control purpose and minimal maintenance. Special gas sample Conditioning systems are used to clean and dry the gas sample for accurate and High performance operation. An Internal Pump draw gas sample into the sensor through a dust particle filter from an intake which can be located at distance up to 40 meter form the monitor. The Sensor and Electronic component are housed in tough aluminium housing\n\nPrinciple\t: \tElectrochemical, TCD (Thermal Conductivity) , NDIR (Non Dispersive Infrared ), Zirconium and Paramagnetic\nRange\t: \t%V/V, % LEL, PPM, Mg/M3\nResolution\t: \t0.1 Unit or 1 Unit (Application based)\nSampling Method\t: \tAuto Suction\n\n\t\t\n\n\t\t", "price": 415000.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 7, "_keywords": [ "application sample gas", "208A Emission Analyzer", "duel wavelength sensor", "Long Life Electrochemical", "High performance operation", "Internal Pump draw gas sample", "adjustable level relay output", "Excellent low level capability", "Duel wavelength Infra red sensor", "Stack Emission Monitoring systems", "user experiences maximum reliability", "Special gas sample Conditioning systems", "reliable multiple gas analyzer solutions", "Multi Parameter Single 320 X 240 Graphics LCD", "Applied Model ATS 208A Continuous Emission Monitoring System" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 30, "imageuri": "https://productimages.withfloats.com/actual/5b694d9849ad1905b5381a79.jpg", "tileimageuri": "https://productimages.withfloats.com/actual/5b694d9849ad1905b5381a79.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2018-08-07T07:43:20.886Z", "updatedon": "2018-08-08T18:47:34Z", "buyonlinelink": null, "producturl": "http://WWW.APPLIEDTECHNOSYSTEM.IN/products/sox-nox-analyzer/30", "availableunits": -1.0, "iscodavailable": true, "isprepaidonlineavailable": false, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": null, "category": "Stack Monitoring System", "tags": [ "Stack Monitoring System", "Emission Monitor", "SO2 Analyzer", "Continuous Gas Analyzer" ], "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": null, "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": null, "gstslab": 0.0, "isnotforsale": false } ], "hasmoreitems": false, "isapirequest": false, "totalresults": 27, "query": null, "floatingpoint": null }

Still searching for
housing?

Still searching for
housing?

Chat with us