"name": " Online Stack Emission Monitor System with dual display",
"description": "Model ATS -208A Gas with dual displayAnalyzer continuously monitors the concentration of gasesranging from 100%V/V down to PPM level. Feature includes a duel wavelengthsensor, Remote Sampling, Graphics LCD Display, adjustable level relay output foralarm and 4-20mAoutput for control purpose and minimal maintenance.Special gas sample Conditioning systems are used to clean and dry the gas samplefor accurate and High performance operation. An Internal Pump draw gas sampleinto the sensor through a dust particle filter from an intake which can be located atdistance up to 40 meter form the monitor.The Sensor and Electronic component are housed in tough aluminium housingFor hazardous area applicationsthe sensor may be mounted remotely in thehazardous areaand safely connected via anzener barrier to the electronics unit inthe safe area. Alternatively the electronicsunit can be supplied in an Explosion proofenclosure.\n\nspacification\n\n· Accuracy : +/- 2%.\n\n· Display : High quality 320 x 264 Graphics LCD\n\n· Sampling : Auto Suction Sampling through Inbuilt Pump\n\n· Digital Output : RS-485\n\n· Zero Calibration: Automatic at instrument start up with fresh air sample.\n\n· Power Supply : Power Supply 230V AC\n\n· Measuring Principle : Dynamic Detection Principle DDP\n\n· Analogue Output : 4-20mA\n\n· Path Length : 0.25 to 10 meter",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": [
"208A Gas",
"Model ATS",
"safe area",
"PPM level",
"The Sensor",
"LCD Display",
"Path Length",
"to 40 meter",
"Auto Suction",
"Inbuilt Pump",
"High quality",
"gas samplefor",
"gas sampleinto",
"Digital Output",
"Remote Sampling",
"anzener barrier",
"control purpose",
"Analogue Output",
"264 Graphics LCD",
"0.25 to 10 meter",
"Zero Calibration",
"electronics unit",
"An Internal Pump",
"fresh air sample",
"minimal maintenance",
"Measuring Principle",
"thehazardous areaand",
"Electronic component",
"dual displayAnalyzer",
"dust particle filter",
"Power Supply 230V AC",
"duel wavelengthsensor",
"Explosion proofenclosure",
"High performance operation",
"tough aluminium housingFor",
"hazardous area applicationsthe",
"Dynamic Detection Principle DDP",
"Online Stack Emission Monitor System",
"adjustable level relay output foralarm",
"Special gas sample Conditioning systems"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 82,
"imageuri": "https://bizimages.withfloats.com/actual/7ab5ae6b53364f3f925f87f2a9faa88d.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/7ab5ae6b53364f3f925f87f2a9faa88d.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2024-08-06T05:28:32.689Z",
"updatedon": "2024-08-06T05:28:32.689Z",
"buyonlinelink": null,
"producturl": "http://WWW.APPLIEDTECHNOSYSTEM.IN/products/-online-stack-emission-monitor-system-with-dual-display/82",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": "",
"category": "Stack Monitoring System",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": "",
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "5ba332cf83fef40001b2ba4f",
"fptag": "APPLIEDTECHNOSYSTEMS",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Broken Bag Detector",
"description": "A Dust particulate monitor is a device that is mounted in the discharge stack of a dust collector and continuously monitors the amount of particulate discharge. The particulate monitor uses a technology known as Triboelectric or Triboelectricity. When two different materials come in contact, it is likely that one will leave with more electrons than it started with and the other will leave with less, this is called Triboelectric Effect. The interaction between the probe and particles produces a charge transfer within the probe. The charge is then converted to an output signal.\n\nThe advanced electronics of the Monitor detect this signal and present it to the operator via a modulating Graphical display.\n\nSpecification :\n\nRange 0-1000 Mg/M3\n\nSensor Base Systems Style\n\nIntegral\n\nRemote\n\nRemote Sensor Enclosure: Cost Aluminum, Electrostatically powder coating\n\nProbe Material: 316 Stainless Steel (Slandered) other materials available\n\nInsulator material: Extended High Performance (PFA) Temperature up to 250 C Ceramic (High temperature up to 550 Deg C )\n\nElectronics 18 – 32 V DC () at the unit\n\n230V AC (Controller)\n\nOutput: 4-20mA & SPDT Relay\n\nProbe Insertion length: 3” to 36” ( 7.6 Cm to 91.4 Cm)\n\nInstallation Weld the supplied fitting into the pipe or Duct and insert Sensor\n\nSensor Mounting Flanged\n\n½” Male NPT\n\nQuick release",
"price": 60500.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 7,
"_keywords": null,
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 59,
"imageuri": "https://productimages.withfloats.com/actual/5c11f2cd022f0d0001610b02.jpg",
"tileimageuri": "https://productimages.withfloats.com/actual/5c11f2cd022f0d0001610b02.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2018-09-20T05:40:31.053Z",
"updatedon": "2018-12-13T05:49:01Z",
"buyonlinelink": null,
"producturl": "http://WWW.APPLIEDTECHNOSYSTEM.IN/products/broken-bag-detector/59",
"availableunits": -1.0,
"iscodavailable": true,
"isprepaidonlineavailable": false,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "Broken Bag Detector",
"tags": [
"Broken Bag Detector",
"Dust Monitor"
],
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": null,
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": null,
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "5ba32e15bb975e00016e0716",
"fptag": "APPLIEDTECHNOSYSTEMS",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Continuous Emissions Monitoring Systems (SPM)",
"description": "Backed with leading–edge technology and experienced professionals, we are offering an extensive range of Continuous Emissions Monitoring Systems (SPM). It is a device that is mounted in the discharge stack of a dust collector and continuously monitors the amount of particulate discharge. Following industry distinct guidelines, we manufacture the entire array by utilizing contemporary machines, modernize technology and prime grade raw material. In order to ensure quality, the entire range is thoroughly tested upon a series of parameters. Apart from this, we offer the entire array in a wide range of specifications as per the precise needs of our clients. \n\nFeatures:\n\n\nEasy to use\nReliable operation\nPrecisely designed\n\n\nOther Details:\n\n\nA Dust particulate monitor is a device that is mounted in the discharge stack of a dust collector and continuously monitors the amount of particulate discharge. The particulate monitor uses a technology known as Triboelectric or Triboelectricity.\nWhen two different materials come in contact, it is likely that one will leave with more electrons than it started with and the other will leave with less, this is called Triboelectric Effect. The interaction between the probe and particles produces a charge transfer within the probe. The charge is then converted to an output signal.\nThe advanced electronics of the Monitor detect this signal and present it to the operator via a modulating Graphical display.\n\nSpecification :\nRange\t0-1000 Mg/M3\nSensor\tBase Systems Style\nIntegral\nRemote\nRemote Sensor Enclosure:\tCost Aluminum, Electrostatically powder coating\nProbe Material:\t316 Stainless Steel (Slandered) other materials available\nInsulator material:\tExtended High Performance (PFA) Temperature up to 250 C Ceramic (High temperature up to 550 Deg C )\nElectronics\t18 – 32 V DC () at the unit\n230V AC (Controller)\nOutput:\t4-20mA SPDT Relay\nProbe Insertion length:\t3” to 36” ( 7.6 Cm to 91.4 Cm)\nInstallation\tWeld the supplied fitting into the pipe or Duct and insert Sensor\nSensor Mounting\tFlanged\n½” Male NPT\nQuick release",
"price": 145500.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": true,
"shipmentduration": 7,
"_keywords": null,
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 54,
"imageuri": "https://productimages.withfloats.com/actual/5ba32e16872a69000171e1f6.jpg",
"tileimageuri": "https://productimages.withfloats.com/actual/5ba32e16872a69000171e1f6.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2018-09-20T05:20:21.598Z",
"updatedon": "2018-12-04T08:24:28Z",
"buyonlinelink": null,
"producturl": "http://WWW.APPLIEDTECHNOSYSTEM.IN/products/continuous-emissions-monitoring-systems-spm-/54",
"availableunits": -1.0,
"iscodavailable": true,
"isprepaidonlineavailable": false,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "Stack Analyzer",
"tags": [
"Stack Analyzer",
"SPM Monitoring Systems",
"Stack Monitoring System,",
"SPM Monitor",
"Dust Monitoring Systems",
"Stack Monitoring Systems"
],
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": null,
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": null,
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "5b7264446d82d50505b27998",
"fptag": "APPLIEDTECHNOSYSTEMS",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Oxygen Analyser",
"description": "Oxygen Analyzer Model ATS-208A\n\nFeatures\n\n· Micro controller based embedded intelligent instruments\n· Long Life Electrochemical sensor\n· Proven technology from gas analyser experts\n\n• ppm or % O2 levels\n\n• Hazardous area options\n\n• Choice of cells for different applications\n\n• Remote or integral sensor\n\n• Choice of sample systems\n\nApplications\n\n• Nitrogen generators\n\n• Inert gas systems\n\n• Air separation\n\n• Furnace atmospheres\n\n• Biogas\n\n• Gloveboxes\n\n• Gasification\n\n• Packaging\n\nThe ATS -208A oxygen analysers have numerous applications in processes requiring the precise measurement of oxygen level. In ppm or % levels, safe areas or hazardous ones, in various process conditions and in differing backgrounds there is a ATS – 208A configuration right for your needs. Options include a choice of outputs, AC or DC versions, alternative oxygen cells or sample conditioning.\n\nOxygen is measured in a wide variety of processes, to confirm its presence or absence. The most common application however is measuring oxygen as an 'impurity' in other gases, e.g. nitrogen generators. Oxygen is required in aerobic processes and also in situations that require user intervention, e.g. to ensure that it is safe to enter a chamber for maintenance work. Some processes will only run efficiently in the absence of oxygen, e.g. furnace atmospheres; others just require a low level of oxygen for safety reasons, e.g. inert gas blanketing.\n\nDifferent electrochemical cells are available to suit the application. The standard A cell has a broad range from high ppm to 50% oxygen. The ‘B’ cell is designed for accuracy at low ppm levels; it will also work at % levels (with a shorter lifetime). The ‘C’ cell is designed for use in % levels of oxygen in the presence of mildly acidic gases, e.g. carbon dioxide, while the ‘D’ cell is perfect for low ppm oxygen applications where hydrogen is present. Applied will be pleased to advise on which cell is most suitable for an application.\n\nA choice of configuration is available. The most convenient and economic is a standard analyser with the cell mounted on the rear. Alternatively, there is remote sensor housing complete with flowmeter and valve. Where cable lengths and/or hazardous area conditions are an issue, the transmitter can be located in the sensor housing\n\nDifferent sample conditioning systems are available, standard or bespoke, according to the process conditions. Filters, pumps and regulators can all be incorporated to deliver the sample in the correct condition. Bypass flow systems enable longer distances from process to analyser to be achieved. Applied engineers are ready to recommend the right system for you on receipt of the full gas stream specification.\n\nFor hazardous area applications the sensor may be mounted remotely in the hazardous area and safely connected via an zener barrier to the electronics unit in the safe area. Alternatively the electronics unit can be supplied in an Explosion proof enclosure.",
"price": 125500.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": [
"oxygen cells",
"low ppm levels",
"oxygen analysers",
"numerous applications",
"electrochemical cells",
"Oxygen Analyzer Model",
"sensor housing complete",
"208A configuration right",
"hazardous area conditions",
"Explosion proof enclosure",
"Long Life Electrochemical",
"various process conditions",
"Bypass flow systems enable",
"low ppm oxygen applications",
"hazardous area applications"
],
"isarchived": false,
"isavailable": false,
"applicationid": null,
"productindex": 39,
"imageuri": "https://productimages.withfloats.com/actual/5c11f4c337862000011ac467.jpg",
"tileimageuri": "https://productimages.withfloats.com/actual/5c11f4c337862000011ac467.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2018-08-14T05:10:28.232Z",
"updatedon": "2018-12-13T05:57:22Z",
"buyonlinelink": null,
"producturl": "http://WWW.APPLIEDTECHNOSYSTEM.IN/products/oxygen-analyser/39",
"availableunits": -1.0,
"iscodavailable": true,
"isprepaidonlineavailable": false,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": null,
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": null,
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "671a3d6ef363c75e9da48bca",
"fptag": "APPLIEDTECHNOSYSTEMS",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Portable Biogas Analyzer Model ATS 201A",
"description": " Portable biogas analyzer Model ATS 201A is a compact, lightweight device designed to measure the composition of biogas, a renewable energy source produced through the anaerobic digestion of organic matter. These analyzers are essential tools for biogas producers, researchers, and quality control professionals.\n\nKey Components and Functions:\nGas Sampling Unit: This component extracts a representative sample of biogas from the production process.\n various gases present in biogas, including:\nMethane (CH4): The primary component of biogas, responsible for its energy content.\nCarbon dioxide (CO2): A byproduct of the digestion process that can reduce the overall energy value of biogas.\nHydrogen sulfide (H2S): A corrosive gas that can damage equipment and contaminate downstream processes.\nOxygen (O2): The presence of oxygen can inhibit the anaerobic digestion process.\nData Processing Unit: This unit processes the sensor signals to provide accurate and reliable measurements of the gas concentrations.\nDisplay: The analyzer typically features a display screen that shows the measured gas concentrations in real-time.\nCommunication Interface: Many analyzers offer connectivity options, such as Bluetooth or Wi-Fi, allowing for data transfer to computers or mobile devices.\nApplications of Portable Biogas Analyzers:\nBiogas Production: Monitoring biogas quality to ensure optimal efficiency and prevent equipment damage.\nResearch and Development: Studying the factors influencing biogas production and developing new technologies.\nQuality Control: Verifying the purity and energy content of biogas before it is used for heating, electricity generation, or fuel.\nEnvironmental Monitoring: Assessing the environmental impact of biogas production and emissions.\nBenefits of Using Portable Biogas Analyzers:\nPortability: Easy to transport and use in various locations.\nAccuracy: Provides reliable measurements of gas concentrations.\nEfficiency: Streamlines biogas quality control processes.\nCost-Effectiveness: Can help identify and address issues that may affect biogas production efficiency.",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": [
"various gases",
"corrosive gas",
"data transfer",
"display screen",
"mobile devices",
"sensor signals",
"Carbon dioxide",
"Key Components",
"organic matter",
"Many analyzers",
"energy content",
"essential tools",
"equipment damage",
"new technologies",
"Hydrogen sulfide",
"biogas producers",
"primary component",
"various locations",
"Gas Sampling Unit",
"optimal efficiency",
"gas concentrations",
"production process",
"environmental impact",
"connectivity options",
"downstream processes",
"Data Processing Unit",
"overall energy value",
"reliable measurements",
"representative sample",
"electricity generation",
"Communication Interface",
"renewable energy source",
"Environmental Monitoring",
"Portable Biogas Analyzers",
"anaerobic digestion process",
"compact, lightweight device",
"biogas production efficiency",
"quality control professionals",
"biogas quality control processes",
"Portable Biogas Analyzer Model ATS 201A"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 86,
"imageuri": "https://bizimages.withfloats.com/actual/3c2ab3d71ea0442e8142e38f0f096b7d.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/3c2ab3d71ea0442e8142e38f0f096b7d.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2024-10-24T12:28:30.388Z",
"updatedon": "2024-10-24T12:28:30.388Z",
"buyonlinelink": null,
"producturl": "http://WWW.APPLIEDTECHNOSYSTEM.IN/products/portable-biogas-analyzer-model-ats-201a/86",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": "ATS 201A",
"category": "Biogas Analyzer",
"tags": [],
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": "",
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 18.0,
"isnotforsale": false
},
{
"_id": "669665cf90fba910d4dd8c65",
"fptag": "APPLIEDTECHNOSYSTEMS",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Hydrogen sulfide (H2S) GAS DETECTOR",
"description": "Specification:\n\nMinium Resolution: 0.1 or 1 unit of the range\nIndication: Digital Continuous\nMounting: wall\nSensor Technology: Appropriate to Application\nDetection Method: Diffusion / Sample Draw Pump\nAccuracy: +/- 2%\nLinearity: +/- 2%\nRelative Humidity: 0-99 % Non-condensing\nResponse Time: ( 90% in 10 seconds)\nSingal Output for Recorder: 0- IV,420 mA (Optional)\nAlarm Setting: High and very High Adjustable over full range\nAlarmCircuits: SPDT 5 AMP 220V Contacts\nControls: Zero , Span, Alarm settin",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": [
"1 unit",
"10 seconds",
"full range",
"0- IV,420 mA",
"Alarm Setting",
"Singal Output",
"Response Time",
"Sample Draw Pump",
"Relative Humidity",
"Sensor Technology",
"Hydrogen sulfide",
"GAS DETECTOR Specification",
"Digital Continuous Mounting",
"Application Detection Method",
"SPDT 5 AMP 220V Contacts Controls"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 78,
"imageuri": "https://bizimages.withfloats.com/actual/d79f06654ad1433bb08dc2215c14e6ff.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/d79f06654ad1433bb08dc2215c14e6ff.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2024-07-16T12:21:35.374Z",
"updatedon": "2024-07-16T12:21:35.374Z",
"buyonlinelink": null,
"producturl": "http://WWW.APPLIEDTECHNOSYSTEM.IN/products/hydrogen-sulfide-h2s-gas-detector/78",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": "",
"category": "H2S GAS",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": "",
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "6690f37b62369a1a08b058c3",
"fptag": "APPLIEDTECHNOSYSTEMS",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "INSITU ZIRCONIA BASED OXYGEN ANALYZER",
"description": "FEATURES \n1)Zirconia oxide sensor, giving real measurement of excess oxygen\n2. Long life zirconium Sensor\n3. Reliable out put , adaptable to close loop control\n4. Easy to Operate\n5. Wide Measurement Range 1PPM to 96%\n6. Easy installation, all hardware supplied with the system.\n7. Completely field repairable.\n8. Digital electronics package in IP 65 housing.\n9. Explosion-proof housing available as option.\n10. Auto & manual calibration facility for zirconium sensor.\n11. Micro controller based digital systems with user friendly\nAPPLICATIONS ·\nGas Manufacturing & Testing Petrochemicals & Chemical Industry ·\n· Exhaust Gas Analysis\n· Food Packing Factory\n· Monitor Vehicle Emission\n· Low oxygen Mesurment at industrial Process ·\n· Steel Plant Air Quality Monitoring, Oxygen Monitoring\n· Laboratories & Institutions\n· Metal Processing Plant\n· Petrochemical & Chemical Industries\n· Pharmaceutical Industries \nTECHNICAL SPECIFICATIONS\nPower supply :-24V ±10% Limited Power Supply\nPower consumption :-700mA maximum @ 24V\nAnalog outputs :-Single or Dual 420mA\nOutput ranges (oxygen) :-0— 25% vol.O2\nOutput ranges (pressure):- 750 — 1260mbar absolute\nRelays (SPST, N/O as std.):- 1 x system alarm (SPST)\n 1 x user configurable O set point alarm\nDigital communications :- RS485 Modbus RTU protocol\nDisplay :-16 character, 2 - line, backlit\n\nOPERATING CONDITIONS\nAmbient temperature:- 20 to +55°C (4 to +131°F)\nAmbient relative humidity :-95% RH\nGas composition Combustion gas from natural gas, biogas or oil\nSample gas temperature:- +700°C (1292°F)\nSample gas flow rate :-4m/s minimum recommended\nCompensated pressure :-750 — 1260mbar absolute",
"price": 230000.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": [
"5% RH",
"25% vol",
"65 housing",
"point alarm",
"natural gas",
"user friendly",
"excess oxygen",
"Analog outputs",
"Combustion gas",
"digital systems",
"Gas composition",
"Micro controller",
"real measurement",
"1 x system alarm",
"O2 Output ranges",
"Chemical Industry",
"Easy installation",
"Gas Manufacturing",
"Power consumption",
"Oxygen Monitoring",
"industrial Process",
"close loop control",
"Chemical Industries",
"Ambient temperature",
"Compensated pressure",
"OPERATING CONDITIONS",
"Exhaust Gas Analysis",
"Low oxygen Mesurment",
"Food Packing Factory",
"Sample gas flow rate",
"1 x user configurable",
"Digital communications",
"Wide Measurement Range",
"Sample gas temperature",
"Metal Processing Plant",
"Explosion-proof housing",
"1)Zirconia oxide sensor",
"1260mbar absolute Relays",
"Monitor Vehicle Emission",
"Dual 420mA Output ranges",
"Pharmaceutical Industries",
"Ambient relative humidity",
"Long life zirconium Sensor",
"Digital electronics package",
"manual calibration facility",
"RS485 Modbus RTU protocol Display",
"Steel Plant Air Quality Monitoring",
"TECHNICAL SPECIFICATIONS Power supply",
"INSITU ZIRCONIA BASED OXYGEN ANALYZER"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 75,
"imageuri": "https://bizimages.withfloats.com/actual/895d17c6f4da464e8654f534e6a43f67.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/895d17c6f4da464e8654f534e6a43f67.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2024-07-12T09:12:27.465Z",
"updatedon": "2024-07-12T09:12:27.465Z",
"buyonlinelink": null,
"producturl": "http://WWW.APPLIEDTECHNOSYSTEM.IN/products/insitu-zirconia-based-oxygen-analyzer/75",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": "",
"category": "OXYGEN ANALYZER",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": "",
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "5ba349358ecf650001949108",
"fptag": "APPLIEDTECHNOSYSTEMS",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Fixed Sulfur Dioxide Gas Leak Monitor - Model ATS 105M",
"description": "Fixed Type Sulfar Dioxide Gas Leak Monitor - Model ATS 105M\nThe Monitor is a single Gas Multipurpose monitor that combines simplicity and high performance in a low cost,low maintenance package.The rugged NEMA 4X or 7x assembly is suitable for a variety of industrial , commercial and general purpose applications to monitor HAZARDOUS,Toxic gases or oxygen in process Flue Gas or Ambient Air.\n\nSpecial Features:\nFast and accurate response, Long Life Application Specific Gas Sensor, Technologies, Solid State Electronics, Continuous Monitoring,Two Alarm Levels, Fail Safe Protection, Recorder Output, Integral or Remote Mounting Sensor, Un-attended Operation, Sampling by Diffusion or sample Draw Pump.Flexibility to fit your application needs, Interfaces with Industry Standard Tranmitters.\n\nSpecification:\nMinium Resolution: 0.1 or 1 unit of the range\nIndication: Digital Continuous\nMounting: wall\nSensor Technology: Appropriate to Application\nDetection Method: Diffusion / Sample Draw Pump\nAccuracy: +/- 2%\nLinearity: +/- 2%\nRelative Humidity: 0-99 % Non-condensing\nResponse Time: ( 90% in 10 seconds)\nsingal Output for Recorder: 0- IV,420 mA (Optional)\nAlarm Setting: High and very High Adjustable over full range\nAlarmCircuits: SPDT 5 AMP 220V Contacts\nControls: Zero , Span, Alarm setting\n",
"price": 36500.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 7,
"_keywords": null,
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 71,
"imageuri": "https://productimages.withfloats.com/actual/5c11f201a81ccb00013290d8.jpg",
"tileimageuri": "https://productimages.withfloats.com/actual/5c11f201a81ccb00013290d8.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2018-09-20T07:16:05.364Z",
"updatedon": "2018-12-13T05:45:37Z",
"buyonlinelink": null,
"producturl": "http://WWW.APPLIEDTECHNOSYSTEM.IN/products/fixed-sulfur-dioxide-gas-leak-monitor-model-ats-105m/71",
"availableunits": -1.0,
"iscodavailable": true,
"isprepaidonlineavailable": false,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "Fixed Gas Leak Monitor",
"tags": [
"Fixed Gas Leak Monitor",
"Sulfur Dioxide Gas Leak Monitor"
],
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": null,
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": null,
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "5ba33f5a94b28c0001ab628b",
"fptag": "APPLIEDTECHNOSYSTEMS",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Online Hydrogen sulfide Gas Leak Detector - ATS 105M",
"description": "Online Hydrogen sulfide Gas Leak Detector - ATS 105M Manfacture in india \nSpecification:\nMinium Resolution: 0.1 or 1 unit of the range\nIndication: Digital Continuous\nMounting: wall\nSensor Technology: Appropriate to Application\nDetection Method: Diffusion / Sample Draw Pump\nAccuracy: +/- 2%\nLinearity: +/- 2%\nRelative Humidity: 0-99 % Non-condensing\nResponse Time: ( 90% in 10 seconds)\nsingal Output for Recorder: 0- IV,420 mA (Optional)\nAlarm Setting: High and very High Adjustable over full range\nAlarmCircuits: SPDT 5 AMP 220V Contacts\nControls: Zero , Span, Alarm setting\n",
"price": 38500.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 7,
"_keywords": null,
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 68,
"imageuri": "https://productimages.withfloats.com/actual/5c11f1c6896c060001a44879.jpg",
"tileimageuri": "https://productimages.withfloats.com/actual/5c11f1c6896c060001a44879.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2018-09-20T06:34:02.183Z",
"updatedon": "2018-12-13T05:44:37Z",
"buyonlinelink": null,
"producturl": "http://WWW.APPLIEDTECHNOSYSTEM.IN/products/online-hydrogen-sulfide-gas-leak-detector-ats-105m/68",
"availableunits": -1.0,
"iscodavailable": true,
"isprepaidonlineavailable": false,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "Hydrogen sulfide Gas Leak Detector",
"tags": [
"Hydrogen sulfide Gas Leak Detector",
"Gas Leak Monitoring System",
"Online Hydrogen sulfide Gas Leak Detector"
],
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": null,
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": null,
"gstslab": 0.0,
"isnotforsale": false
}
],
"hasmoreitems": false,
"isapirequest": false,
"totalresults": 27,
"query": null,
"floatingpoint": null
}