Preview

This is your website preview.

Currently it only shows your basic business info. Start adding relevant business details such as description, images and products or services to gain your customers attention by using Boost 360 android app / iOS App / web portal.

APPLIEDTECHNOSYSTEMS 590481e09e768b0560d08878 Products https://www.appliedtechnosystem.in
{ "products": [ { "_id": "5ba33e3be42f7e0001bcc3dd", "fptag": "APPLIEDTECHNOSYSTEMS", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "Fixed Type Nitrogen dioxide Gas Leak Detector ATS 105M", "description": "Fixed Type Nitrogen dioxide Gas Leak Detector - ATS 105M (NOx Analyzer)\n\nModel ATS 105M single channel digital control modules are designed to supervise and display the satus of a single intergal or remote sensor Model ATS 109TD assembly. Model ATS 109TD is housed in a NEMA 4 x wall mount enclosure or Ex -proof enclosure. Model ATS 105M Single channel controllers interface with industry standred two or three wire 4-20mA sensor or other standred voltage / current sensor transmitters and provide the user with concentration display and two independent adjustable alarms levels. The Graphics display can read the concentration. LEDs on the front panel provide indication of all three alarms.\n\nThe alarm relays can be programmed to be either latching or non-latching and to activate either as a rising or failing alarm. The relays are SPDT Form C type rated at 5 Amps. to provide direct alarm action, reducing the need for interposing relays . Local Alarm devices can be connected to the configurable on board alarms.The Fail safe supervisory provides a reliable indicaiton that the Monitor is fully operational. The \"Fail Safe\" design monitors the input power and sttaus of the Power suppy for the e amplifiers.A failure of any one of these functions illuminates a \" Fault\" Light Emitting Diode.\n\nSpecification:\nMinium Resolution: 0.1 or 1 unit of the range\nIndication: Digital Continuous\nMounting: wall\nSensor Technology: Appropriate to Application\nDetection Method: Diffusion / Sample Draw Pump\nAccuracy: +/- 2%\nLinearity: +/- 2%\nRelative Humidity: 0-99 % Non-condensing\nResponse Time: ( 90% in 10 seconds)\nsingal Output for Recorder: 0- IV,420 mA (Optional)\nAlarm Setting: High and very High Adjustable over full range\nAlarmCircuits: SPDT 5 AMP 220V Contacts\nControls: Zero , Span, Alarm setting", "price": 35500.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 7, "_keywords": null, "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 66, "imageuri": "https://productimages.withfloats.com/actual/5c11f39010ec3d000193ee0f.jpg", "tileimageuri": "https://productimages.withfloats.com/actual/5c11f39010ec3d000193ee0f.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2018-09-20T06:29:15.96Z", "updatedon": "2018-12-13T05:52:15Z", "buyonlinelink": null, "producturl": "http://WWW.APPLIEDTECHNOSYSTEM.IN/products/fixed-type-nitrogen-dioxide-gas-leak-detector-ats-105m/66", "availableunits": -1.0, "iscodavailable": true, "isprepaidonlineavailable": false, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": null, "category": "Gas Leak Detection System", "tags": [ "Gas Leak Detection System", "Gas Analyzer", "NOx Leak Detector", "Gas Leak Monitoring System", "Fixed Type Nitrogen dioxide Gas Leak Detector", "SOx Leak Detector" ], "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": null, "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": null, "gstslab": 0.0, "isnotforsale": false }, { "_id": "5ba33da09679aa00015c283c", "fptag": "APPLIEDTECHNOSYSTEMS", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "Online Nitrogen Oxide (NO2) Gas Leak Detector ATS 105M", "description": "Online Nitrogen Oxide (NO2) Gas Leak Detector ATS 105M\n\nModel ATS 105M single channel digital control modules are designed to supervise and display the satus of a single intergal or remote sensor Model ATS 109TD assembly. Model ATS 109TD is housed in a NEMA 4 x wall mount enclosure or Ex -proof enclosure. Model ATS 105M Single channel controllers interface with industry standred two or three wire 4-20mA sensor or other standred voltage / current sensor transmitters and provide the user with concentration display and two independent adjustable alarms levels. The Graphics display can read the concentration. LEDs on the front panel provide indication of all three alarms.\n\nThe alarm relays can be programmed to be either latching or non-latching and to activate either as a rising or failing alarm. The relays are SPDT Form C type rated at 5 Amps. to provide direct alarm action, reducing the need for interposing relays . Local Alarm devices can be connected to the configurable on board alarms.The Fail safe supervisory provides a reliable indicaiton that the Monitor is fully operational. The \"Fail Safe\" design monitors the input power and sttaus of the Power suppy for the e amplifiers.A failure of any one of these functions illuminates a \" Fault\" Light Emitting Diode.\n\nSpecification:\n\nMinimum Resolution: 0.1 or 1 unit of the range\nIndication: Digital Continuous\nMounting: wall\nSensor Technology: Appropriate to Application\nDetection Method: Diffusion / Sample Draw Pump\nAccuracy: +/- 2%\nLinearity: +/- 2%\nRelative Humidity: 0-99 % Non-condensing\nResponse Time: ( 90% in 10 seconds)\nSingal Output for Recorder: 0- IV,420 mA (Optional)\nAlarm Setting: High and very High Adjustable over full range\nAlarm Circuits: SPDT 5 AMP 220V Contacts\nControls: Zero , Span, Alarm setting\n", "price": 35500.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 7, "_keywords": null, "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 65, "imageuri": "https://productimages.withfloats.com/actual/5c11f22c0cbfd500019068ef.jpg", "tileimageuri": "https://productimages.withfloats.com/actual/5c11f22c0cbfd500019068ef.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2018-09-20T06:26:40.901Z", "updatedon": "2018-12-13T05:46:19Z", "buyonlinelink": null, "producturl": "http://WWW.APPLIEDTECHNOSYSTEM.IN/products/online-nitrogen-oxide-no2-gas-leak-detector-ats-105m/65", "availableunits": -1.0, "iscodavailable": true, "isprepaidonlineavailable": false, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": null, "category": "NO2 Leak Detector", "tags": [ "NO2 Leak Detector", "NOx Gas Analyzer", "Fixed Type Gas Monitoring System", "Gas Leak Monitor" ], "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": null, "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": null, "gstslab": 0.0, "isnotforsale": false }, { "_id": "5b850ef4a47c690556e36962", "fptag": "APPLIEDTECHNOSYSTEMS", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "Handheld Dust Monitor", "description": "We have gained a remarkable position in the industry by offering a qualitative assortment of Handheld Dust Monitor that is used to monitor the suspended Particulate concentration in the air. The offered monitor is manufactured employing high-end technology and well-tested components in observance to industry defined guidelines. Apart from this, the entire range is scrupulously tested under the strict inspection of our quality controllers. This range can be availed from us in various specifications at market leading prices.\n\nFeatures:\n\n•Long service life\n•Precisely design\n•Require less maintenance\nOther Details:\n\n•Sampling dust and particulate matter is important as dust and particulate matter can affect the health of humans, as well as the natural environment.\n•Dust and particulate matter can cause respiratory problems when breathed in by humans. Dust and particulates above 10 micrometer (PM10) are filtered and generally do not enter the lungs.\n•Dust and particulate matter that is smaller than 10 micrometers (PM10, PM2.5, PM1.0) can enter into the Alveoli where gas exchange occurs.\n•This PM2.5 is more dangerous as it can affect the exchange of gases within the lungs and even penetrate the lung into the blood stream and cause other health issues.\n•PM10 , PM2.5 and PM1.0 are the normal sampling standards found throughout the world, they represent the particulate pollution that effects human health and thus sampling them provides an accurate insight into how dust and particulate matter effect human health.\n•Handheld/Portable PM Monitor is used to monitor the suspended Particulate concentration in the air with measuring range 0.001mg/M3 to 10 mg/M3.\n•It adopts optical scattering technique. This type of Product has many advantages, such as fast detection speed, high accuracy, light and small, easy operation, measuring and displaying of 3 channels at the same time.\n•It adopts the method of automatic measurement, improving the work efficiency effectively.\n\n\nSpecification :\n\nMeasuring principle Optical scattering technology\n\nLight Source Laser Diode\n\nDetection Range 0.001 – 10mg/m3\n\nDisplay LCD\n\nSize Channel PM10, PM2.5, PM1.0\n\nFlow Rate 2.83L/min (Imported Pump)\n\nSample Time 0-9999s Selectable\n\nZero Count\n\nPrinter External thermal printer\n\nData Storage 1000\n\nOperating Time 5 hours\n\nOutside Dim 130*220*45(Wide*High*Deep)\n\nWeight 0.6kg\n\nTemperature 15degree Celsius\n\nHumidity\n\nAtmosphere Pressure 86-106Kpa", "price": 135500.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 7, "_keywords": [ "accurate insight", "strict inspection", "principle Optical", "quality controllers", "remarkable position", "effects human health", "Handheld Dust Monitor", "particulate pollution", "automatic measurement", "various specifications", "qualitative assortment", "Particulate concentration", "normal sampling standards", "cause respiratory problems", "particulate matter effect human" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 49, "imageuri": "https://productimages.withfloats.com/actual/5c11f416cf760c0001e037d1.jpg", "tileimageuri": "https://productimages.withfloats.com/actual/5c11f416cf760c0001e037d1.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2018-08-28T08:59:32.218Z", "updatedon": "2018-12-13T05:54:30Z", "buyonlinelink": null, "producturl": "http://WWW.APPLIEDTECHNOSYSTEM.IN/products/handheld-dust-monitor/49", "availableunits": -1.0, "iscodavailable": true, "isprepaidonlineavailable": false, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": null, "category": "PM Monitor", "tags": [ "PM Monitor", "Indoor Air Quality Monitor", "Handhel Dust Monitor", "Dust Monitor", "Portable Dust Monitor" ], "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": null, "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": null, "gstslab": 0.0, "isnotforsale": false }, { "_id": "67860f1564562081687aa3ee", "fptag": "APPLIEDTECHNOSYSTEMS", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "CO2 Gas Analyzer ", "description": "A CO2 Gas Analyzer is a specialized device designed to measure the concentration of carbon dioxide (CO2) in gases, such as in the air or exhaust gases from combustion processes. These analyzers are used in various industries and applications, including environmental monitoring, industrial process control, and scientific research.", "price": 0.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 5, "_keywords": [ "exhaust gases", "scientific research", "combustion processes", "carbon dioxide co2", "specialized device designed", "co2 gas analyzer" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 89, "imageuri": "", "tileimageuri": "", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2025-01-14T07:15:33.741Z", "updatedon": "2025-01-14T07:15:33.741Z", "buyonlinelink": null, "producturl": "http://WWW.APPLIEDTECHNOSYSTEM.IN/products/co2-gas-analyzer-/89", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": false, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": null, "category": null, "tags": null, "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": null, "paymenttype": "None", "producttype": "products", "hsncode": null, "gstslab": 0.0, "isnotforsale": false }, { "_id": "671a3d6ef363c75e9da48bca", "fptag": "APPLIEDTECHNOSYSTEMS", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "Portable Biogas Analyzer Model ATS 201A", "description": " Portable biogas analyzer Model ATS 201A is a compact, lightweight device designed to measure the composition of biogas, a renewable energy source produced through the anaerobic digestion of organic matter. These analyzers are essential tools for biogas producers, researchers, and quality control professionals.\n\nKey Components and Functions:\nGas Sampling Unit: This component extracts a representative sample of biogas from the production process.\n various gases present in biogas, including:\nMethane (CH4): The primary component of biogas, responsible for its energy content.\nCarbon dioxide (CO2): A byproduct of the digestion process that can reduce the overall energy value of biogas.\nHydrogen sulfide (H2S): A corrosive gas that can damage equipment and contaminate downstream processes.\nOxygen (O2): The presence of oxygen can inhibit the anaerobic digestion process.\nData Processing Unit: This unit processes the sensor signals to provide accurate and reliable measurements of the gas concentrations.\nDisplay: The analyzer typically features a display screen that shows the measured gas concentrations in real-time.\nCommunication Interface: Many analyzers offer connectivity options, such as Bluetooth or Wi-Fi, allowing for data transfer to computers or mobile devices.\nApplications of Portable Biogas Analyzers:\nBiogas Production: Monitoring biogas quality to ensure optimal efficiency and prevent equipment damage.\nResearch and Development: Studying the factors influencing biogas production and developing new technologies.\nQuality Control: Verifying the purity and energy content of biogas before it is used for heating, electricity generation, or fuel.\nEnvironmental Monitoring: Assessing the environmental impact of biogas production and emissions.\nBenefits of Using Portable Biogas Analyzers:\nPortability: Easy to transport and use in various locations.\nAccuracy: Provides reliable measurements of gas concentrations.\nEfficiency: Streamlines biogas quality control processes.\nCost-Effectiveness: Can help identify and address issues that may affect biogas production efficiency.", "price": 0.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 0, "_keywords": [ "various gases", "corrosive gas", "data transfer", "display screen", "mobile devices", "sensor signals", "Carbon dioxide", "Key Components", "organic matter", "Many analyzers", "energy content", "essential tools", "equipment damage", "new technologies", "Hydrogen sulfide", "biogas producers", "primary component", "various locations", "Gas Sampling Unit", "optimal efficiency", "gas concentrations", "production process", "environmental impact", "connectivity options", "downstream processes", "Data Processing Unit", "overall energy value", "reliable measurements", "representative sample", "electricity generation", "Communication Interface", "renewable energy source", "Environmental Monitoring", "Portable Biogas Analyzers", "anaerobic digestion process", "compact, lightweight device", "biogas production efficiency", "quality control professionals", "biogas quality control processes", "Portable Biogas Analyzer Model ATS 201A" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 86, "imageuri": "https://bizimages.withfloats.com/actual/3c2ab3d71ea0442e8142e38f0f096b7d.jpg", "tileimageuri": "https://bizimages.withfloats.com/actual/3c2ab3d71ea0442e8142e38f0f096b7d.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2024-10-24T12:28:30.388Z", "updatedon": "2024-10-24T12:28:30.388Z", "buyonlinelink": null, "producturl": "http://WWW.APPLIEDTECHNOSYSTEM.IN/products/portable-biogas-analyzer-model-ats-201a/86", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": true, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": "ATS 201A", "category": "Biogas Analyzer", "tags": [], "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": "", "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": "", "gstslab": 18.0, "isnotforsale": false }, { "_id": "67123d976774968455a7bbbc", "fptag": "APPLIEDTECHNOSYSTEMS", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "Portable Oxygen Gas Purity Analyzer", "description": "Portable oxygen gas purity analyzer Model ATS 202A is a specialized instrument designed to accurately measure the concentration of oxygen in gas mixtures. It's a crucial tool in various industries, including-\n\nMedical: Ensuring the purity of oxygen supplied to patients   \n\nIndustrial: Monitoring oxygen levels in industrial processes   \n\nEnvironmental: Assessing air quality and oxygen levels in enclosed spaces   \n\nResearch: Conducting scientific experiments that require precise oxygen control\n\nSpecifications-:\nRange - 0-100% V/V\nMinimum Resolution : 0.01 % \nReadout : 128 x 64 Graphics LCD\nSampling Method : In Built Suction Pump\nDetection Principle : Thermal Conductivity / Infrared.\nAccuracy : +/- 2% of Full Scale.\nAlarms : Audible", "price": 0.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 0, "_keywords": [ "Full Scale", "air quality", "crucial tool", "gas mixtures", "oxygen levels", "Model ATS 202A", "Minimum Resolution", "various industries", "Thermal Conductivity", "industrial processes", "patients   Industrial", "scientific experiments", "specialized instrument", "enclosed spaces   Research", "Suction Pump Detection Principle", "Portable Oxygen Gas Purity Analyzer", "Portable oxygen gas purity analyzer", "precise oxygen control Specifications", "128 x 64 Graphics LCD Sampling Method" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 83, "imageuri": "https://bizimages.withfloats.com/actual/3572c0a3187b4cd8a458de67d742ac2e.jpg", "tileimageuri": "https://bizimages.withfloats.com/actual/3572c0a3187b4cd8a458de67d742ac2e.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2024-10-18T10:51:03.271Z", "updatedon": "2024-10-18T10:51:03.271Z", "buyonlinelink": null, "producturl": "http://WWW.APPLIEDTECHNOSYSTEM.IN/products/portable-oxygen-gas-purity-analyzer/83", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": true, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": "", "category": "Purity Analyzer", "tags": null, "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": "", "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": "", "gstslab": 0.0, "isnotforsale": false }, { "_id": "66b1b4808cf0f2194c135b73", "fptag": "APPLIEDTECHNOSYSTEMS", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": " Online Stack Emission Monitor System with dual display", "description": "Model ATS -208A Gas with dual displayAnalyzer continuously monitors the concentration of gasesranging from 100%V/V down to PPM level. Feature includes a duel wavelengthsensor, Remote Sampling, Graphics LCD Display, adjustable level relay output foralarm and 4-20mAoutput for control purpose and minimal maintenance.Special gas sample Conditioning systems are used to clean and dry the gas samplefor accurate and High performance operation. An Internal Pump draw gas sampleinto the sensor through a dust particle filter from an intake which can be located atdistance up to 40 meter form the monitor.The Sensor and Electronic component are housed in tough aluminium housingFor hazardous area applicationsthe sensor may be mounted remotely in thehazardous areaand safely connected via anzener barrier to the electronics unit inthe safe area. Alternatively the electronicsunit can be supplied in an Explosion proofenclosure.\n\nspacification\n\n· Accuracy : +/- 2%.\n\n· Display : High quality 320 x 264 Graphics LCD\n\n· Sampling : Auto Suction Sampling through Inbuilt Pump\n\n· Digital Output : RS-485\n\n· Zero Calibration: Automatic at instrument start up with fresh air sample.\n\n· Power Supply : Power Supply 230V AC\n\n· Measuring Principle : Dynamic Detection Principle DDP\n\n· Analogue Output : 4-20mA\n\n· Path Length : 0.25 to 10 meter", "price": 0.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 0, "_keywords": [ "208A Gas", "Model ATS", "safe area", "PPM level", "The Sensor", "LCD Display", "Path Length", "to 40 meter", "Auto Suction", "Inbuilt Pump", "High quality", "gas samplefor", "gas sampleinto", "Digital Output", "Remote Sampling", "anzener barrier", "control purpose", "Analogue Output", "264 Graphics LCD", "0.25 to 10 meter", "Zero Calibration", "electronics unit", "An Internal Pump", "fresh air sample", "minimal maintenance", "Measuring Principle", "thehazardous areaand", "Electronic component", "dual displayAnalyzer", "dust particle filter", "Power Supply 230V AC", "duel wavelengthsensor", "Explosion proofenclosure", "High performance operation", "tough aluminium housingFor", "hazardous area applicationsthe", "Dynamic Detection Principle DDP", "Online Stack Emission Monitor System", "adjustable level relay output foralarm", "Special gas sample Conditioning systems" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 82, "imageuri": "https://bizimages.withfloats.com/actual/7ab5ae6b53364f3f925f87f2a9faa88d.jpg", "tileimageuri": "https://bizimages.withfloats.com/actual/7ab5ae6b53364f3f925f87f2a9faa88d.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2024-08-06T05:28:32.689Z", "updatedon": "2024-08-06T05:28:32.689Z", "buyonlinelink": null, "producturl": "http://WWW.APPLIEDTECHNOSYSTEM.IN/products/-online-stack-emission-monitor-system-with-dual-display/82", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": true, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": "", "category": "Stack Monitoring System", "tags": null, "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": "", "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": "", "gstslab": 0.0, "isnotforsale": false }, { "_id": "6696411ae135800a3c92b3d1", "fptag": "APPLIEDTECHNOSYSTEMS", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "combustible gas detector ", "description": "We are an acclaimed name engaged in offering our precious clients a superior quality range of Combustible Gas Monitor. Our offered monitor is manufactured by our experts using high grade raw material and advanced technology in conformity with the industry quality standards. In addition to this, our provided monitor undergoes different tests under the supervision of quality controllers to ensure its excellence at clients' end. It is portable single gas detectors are capable of detecting Methane ,Oxygen, Toxic, and Combustible gases making them ideal for use in various environments. Clients can avail these tanks from us at market leading rates.\n\nFeatures:\nLow power consumption\nSmooth functioning\nHigh functionality\n\nSpecifications:\n\nPrinciple\tElectrochemical, Solid State Semiconductor and PID (Photo Ionization)\nRange\t%V/V, %LEL, PPM, PPB or mg/M3\nResolution\t0.1 Unit or 1 Unit (Application based)\nSampling Method\tDiffusion, Auto Suction or Direct Plug In\nDisplay\t128 X 64 Graphics LCD\nAlarm\tTwo Levels Low High, Visual and Audible\nPower Source\tBuilt in Lithium Rechargeable battery\nAccuracy\t+/2%\nResponse Time\t<5 Second\nFlow Rate\t2.84 L/M\nData Storage\t1000 or 10000\nSensor Life\t2-3 Years\nOperating Time\t6 -8 hours\nEnvironmental\t\nTemperature\t15degree Celsius\nHumidity\t< 85%RH\nAtmosphere Pressure\t86- 106Kpa\nHousing\tHigh Impact Plastic\nDimension in mm\t115 (W) X 180 (H) X 60(D)\nWeight\t0.6 KG\nWarranty\tOne Year", "price": 0.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 0, "_keywords": [ "0.1 Unit", "Two Levels", "Direct Plug", "clients' end", "Data Storage", "Auto Suction", "Power Source", "Weight 0.6 KG", "Response Time", "acclaimed name", "different tests", "precious clients", "Photo Ionization", "Second Flow Rate", "Combustible gases", "Warranty One Year", "Smooth functioning", "Atmosphere Pressure", "advanced technology", "quality controllers", "various environments", "market leading rates", "Low power consumption", "superior quality range", "Combustible Gas Monitor", "high grade raw material", "combustible gas detector", "Principle Electrochemical", "Sampling Method Diffusion", "Solid State Semiconductor", "industry quality standards", "Temperature 15degree Celsius", "Lithium Rechargeable battery", "portable single gas detectors", "High functionality Specifications", "Display 128 X 64 Graphics LCD Alarm", "Sensor Life 2-3 Years Operating Time", "106Kpa Housing High Impact Plastic Dimension" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 76, "imageuri": "https://bizimages.withfloats.com/actual/15080da57fa84cbc95b08da035f1a660.jpg", "tileimageuri": "https://bizimages.withfloats.com/actual/15080da57fa84cbc95b08da035f1a660.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2024-07-16T09:44:58.813Z", "updatedon": "2024-07-16T09:44:58.813Z", "buyonlinelink": null, "producturl": "http://WWW.APPLIEDTECHNOSYSTEM.IN/products/combustible-gas-detector-/76", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": true, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": "", "category": "combustible", "tags": null, "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": "", "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": "", "gstslab": 0.0, "isnotforsale": false }, { "_id": "6690f37b62369a1a08b058c3", "fptag": "APPLIEDTECHNOSYSTEMS", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "INSITU ZIRCONIA BASED OXYGEN ANALYZER", "description": "FEATURES \n1)Zirconia oxide sensor, giving real measurement of excess oxygen\n2. Long life zirconium Sensor\n3. Reliable out put , adaptable to close loop control\n4. Easy to Operate\n5. Wide Measurement Range 1PPM to 96%\n6. Easy installation, all hardware supplied with the system.\n7. Completely field repairable.\n8. Digital electronics package in IP 65 housing.\n9. Explosion-proof housing available as option.\n10. Auto & manual calibration facility for zirconium sensor.\n11. Micro controller based digital systems with user friendly\nAPPLICATIONS ·\nGas Manufacturing & Testing Petrochemicals & Chemical Industry ·\n· Exhaust Gas Analysis\n· Food Packing Factory\n· Monitor Vehicle Emission\n· Low oxygen Mesurment at industrial Process ·\n· Steel Plant Air Quality Monitoring, Oxygen Monitoring\n· Laboratories & Institutions\n· Metal Processing Plant\n· Petrochemical & Chemical Industries\n· Pharmaceutical Industries \nTECHNICAL SPECIFICATIONS\nPower supply :-24V ±10% Limited Power Supply\nPower consumption :-700mA maximum @ 24V\nAnalog outputs :-Single or Dual 420mA\nOutput ranges (oxygen) :-0— 25% vol.O2\nOutput ranges (pressure):- 750 — 1260mbar absolute\nRelays (SPST, N/O as std.):- 1 x system alarm (SPST)\n 1 x user configurable O set point alarm\nDigital communications :- RS485 Modbus RTU protocol\nDisplay :-16 character, 2 - line, backlit\n\nOPERATING CONDITIONS\nAmbient temperature:- 20 to +55°C (4 to +131°F)\nAmbient relative humidity :-95% RH\nGas composition Combustion gas from natural gas, biogas or oil\nSample gas temperature:- +700°C (1292°F)\nSample gas flow rate :-4m/s minimum recommended\nCompensated pressure :-750 — 1260mbar absolute", "price": 230000.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 0, "_keywords": [ "5% RH", "25% vol", "65 housing", "point alarm", "natural gas", "user friendly", "excess oxygen", "Analog outputs", "Combustion gas", "digital systems", "Gas composition", "Micro controller", "real measurement", "1 x system alarm", "O2 Output ranges", "Chemical Industry", "Easy installation", "Gas Manufacturing", "Power consumption", "Oxygen Monitoring", "industrial Process", "close loop control", "Chemical Industries", "Ambient temperature", "Compensated pressure", "OPERATING CONDITIONS", "Exhaust Gas Analysis", "Low oxygen Mesurment", "Food Packing Factory", "Sample gas flow rate", "1 x user configurable", "Digital communications", "Wide Measurement Range", "Sample gas temperature", "Metal Processing Plant", "Explosion-proof housing", "1)Zirconia oxide sensor", "1260mbar absolute Relays", "Monitor Vehicle Emission", "Dual 420mA Output ranges", "Pharmaceutical Industries", "Ambient relative humidity", "Long life zirconium Sensor", "Digital electronics package", "manual calibration facility", "RS485 Modbus RTU protocol Display", "Steel Plant Air Quality Monitoring", "TECHNICAL SPECIFICATIONS Power supply", "INSITU ZIRCONIA BASED OXYGEN ANALYZER" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 75, "imageuri": "https://bizimages.withfloats.com/actual/895d17c6f4da464e8654f534e6a43f67.jpg", "tileimageuri": "https://bizimages.withfloats.com/actual/895d17c6f4da464e8654f534e6a43f67.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2024-07-12T09:12:27.465Z", "updatedon": "2024-07-12T09:12:27.465Z", "buyonlinelink": null, "producturl": "http://WWW.APPLIEDTECHNOSYSTEM.IN/products/insitu-zirconia-based-oxygen-analyzer/75", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": true, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": "", "category": "OXYGEN ANALYZER", "tags": null, "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": "", "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": "", "gstslab": 0.0, "isnotforsale": false } ], "hasmoreitems": false, "isapirequest": false, "totalresults": 27, "query": null, "floatingpoint": null }

Still searching for
cpcb central pollution control board?

Still searching for
cpcb central pollution control board?

Chat with us