Currently it only shows your basic business info. Start adding relevant business details such as description, images and products or services to gain your customers attention by using Boost 360
android app
/
iOS App/ web portal.
{
"products": [
{
"_id": "66b1b4808cf0f2194c135b73",
"fptag": "APPLIEDTECHNOSYSTEMS",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": " Online Stack Emission Monitor System with dual display",
"description": "Model ATS -208A Gas with dual displayAnalyzer continuously monitors the concentration of gasesranging from 100%V/V down to PPM level. Feature includes a duel wavelengthsensor, Remote Sampling, Graphics LCD Display, adjustable level relay output foralarm and 4-20mAoutput for control purpose and minimal maintenance.Special gas sample Conditioning systems are used to clean and dry the gas samplefor accurate and High performance operation. An Internal Pump draw gas sampleinto the sensor through a dust particle filter from an intake which can be located atdistance up to 40 meter form the monitor.The Sensor and Electronic component are housed in tough aluminium housingFor hazardous area applicationsthe sensor may be mounted remotely in thehazardous areaand safely connected via anzener barrier to the electronics unit inthe safe area. Alternatively the electronicsunit can be supplied in an Explosion proofenclosure.\n\nspacification\n\n· Accuracy : +/- 2%.\n\n· Display : High quality 320 x 264 Graphics LCD\n\n· Sampling : Auto Suction Sampling through Inbuilt Pump\n\n· Digital Output : RS-485\n\n· Zero Calibration: Automatic at instrument start up with fresh air sample.\n\n· Power Supply : Power Supply 230V AC\n\n· Measuring Principle : Dynamic Detection Principle DDP\n\n· Analogue Output : 4-20mA\n\n· Path Length : 0.25 to 10 meter",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": [
"208A Gas",
"Model ATS",
"safe area",
"PPM level",
"The Sensor",
"LCD Display",
"Path Length",
"to 40 meter",
"Auto Suction",
"Inbuilt Pump",
"High quality",
"gas samplefor",
"gas sampleinto",
"Digital Output",
"Remote Sampling",
"anzener barrier",
"control purpose",
"Analogue Output",
"264 Graphics LCD",
"0.25 to 10 meter",
"Zero Calibration",
"electronics unit",
"An Internal Pump",
"fresh air sample",
"minimal maintenance",
"Measuring Principle",
"thehazardous areaand",
"Electronic component",
"dual displayAnalyzer",
"dust particle filter",
"Power Supply 230V AC",
"duel wavelengthsensor",
"Explosion proofenclosure",
"High performance operation",
"tough aluminium housingFor",
"hazardous area applicationsthe",
"Dynamic Detection Principle DDP",
"Online Stack Emission Monitor System",
"adjustable level relay output foralarm",
"Special gas sample Conditioning systems"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 82,
"imageuri": "https://bizimages.withfloats.com/actual/7ab5ae6b53364f3f925f87f2a9faa88d.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/7ab5ae6b53364f3f925f87f2a9faa88d.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2024-08-06T05:28:32.689Z",
"updatedon": "2024-08-06T05:28:32.689Z",
"buyonlinelink": null,
"producturl": "http://WWW.APPLIEDTECHNOSYSTEM.IN/products/-online-stack-emission-monitor-system-with-dual-display/82",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": "",
"category": "Stack Monitoring System",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": "",
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "5b6ea828b5dfa70508cd4124",
"fptag": "APPLIEDTECHNOSYSTEMS",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Online Stack Monitoring Systems",
"description": "\nApplied Techno Systems offer comprehensive range of stack gas Analyzer Portable and Continuous for the analysis of stack/flue gases in exhaust, boiler and combustion process. Model ATS- 206A Flue gas Analyzer measure the flue gases after placing its probe into stack or appliance exhaust and see the concentration of Oxygen (O2), Carbon Monoxide (CO) Carbon Dioxide (CO2). Efficient combustion also reduces emission of pollutants such as nitric oxide (NO), nitrogen dioxide (NO2), sulphur dioxide (SO2), and particulate matter. A gas analyzer will also help measure various gas pollutants in the exhaust for environmental reasons.\n\n· Microcontroller based embedded intelligent instruments\n\n· Continuous Monitoring of CO2 ,CH4, CO, O2, SO2, NOX (NO NO2), H2, H2S, N2\n\n· Duel wavelength Infra red sensor for Long terms accuracy and stability\n\n· Long Life Electrochemical sensor\n\n· Six Gas Analysis in Single Analyser\n\n· Multi Parameter Single 320 X 240 Graphics LCD Display\n\n· Self diagnostic & Self integrity check\n\n· RS 232/RS 485 and USB Computer Interface\n\n· Excellent low level capability for NOX and SO2 Measurement\n\n· For most of the application sample gas is cooled and dried inside the sampling conditioning systems to avoid the Heated Sample Line.\n\n· Analog 4-20mA output for each gas\n\nModel ATS- 208A Emission Analyzer continuously monitors the concentration of gases ranging from 100%V/V down to PPM level. Feature includes a duel wavelength sensor, Remote Sampling, Graphics LCD Display, adjustable level relay output for alarm and 4-20mA output for control purpose and minimal maintenance.\n\nSpecial gas sample Conditioning systems are used to clean and dry the gas sample for accurate and High performance operation. An Internal Pump draw gas sample into the sensor through a dust particle filter from an intake which can be located at distance up to 40 meter form the monitor.\n\nThe Sensor and Electronic component are housed in tough aluminium housing\n\nSpecifications:\n\nPrinciple: Electrochemical, TCD (Thermal Conductivity) , NDIR (Non Dispersive Infrared ), Zirconium and Paramagnetic\n\nRange: %V/V, % LEL, PPM, Mg/M3\n\nResolution: 0.1 Unit or 1 Unit (Application based)\n\nSampling Method: Auto Suction\n\nDisplay: 320 X 264 Graphic LCD",
"price": 325100.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": [
"Graphics LCD Display",
"320 X 264 Graphic LCD",
"application sample gas",
"duel wavelength sensor",
"208A Emission Analyzer",
"Long Life Electrochemical",
"High performance operation",
"stack gas Analyzer Portable",
"Internal Pump draw gas sample",
"adjustable level relay output",
"206A Flue gas Analyzer measure",
"measure various gas pollutants",
"Excellent low level capability",
"gas sample Conditioning systems",
"Multi Parameter Single 320 X 240 Graphics LCD"
],
"isarchived": false,
"isavailable": false,
"applicationid": null,
"productindex": 38,
"imageuri": "https://productimages.withfloats.com/actual/5b8500c6016722053c706450.jpg",
"tileimageuri": "https://productimages.withfloats.com/actual/5b8500c6016722053c706450.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2018-08-11T09:11:04.461Z",
"updatedon": "2018-08-28T07:59:01Z",
"buyonlinelink": null,
"producturl": "http://WWW.APPLIEDTECHNOSYSTEM.IN/products/online-stack-monitoring-systems/38",
"availableunits": -1.0,
"iscodavailable": true,
"isprepaidonlineavailable": false,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "stack monitoring system",
"tags": [
"stack monitoring system",
"gas analyzer",
"continuous emission monitoring systems"
],
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": null,
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": null,
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "5b6ea5f52802af051d2188af",
"fptag": "APPLIEDTECHNOSYSTEMS",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Emissions Gas Analyzer",
"description": "Emission Analyser \nModel ATS- 208A Continuous Emission Analyzer continuously monitors the concentration of gases ranging from 100%V/V down to PPM level. Feature includes a duel wavelength sensor, Remote Sampling, Graphics LCD Display, adjustable level relay output for alarm and 4-20mA output for control purpose and minimal maintenance. Special gas sample Conditioning systems are used to clean and dry the gas sample for accurate and High performance operation. An Internal Pump draw gas sample into the sensor through a dust particle filter from an intake which can be located at distance up to 40 meter form the monitor.\n\nFeatures:\n\n Microcontroller based embedded intelligent instruments\n Continuous Monitoring of CO2 ,CH4, CO, O2, SO2, HF, NOX (NO NO2), H2, H2S, N2\n Duel wavelength Infra red sensor for Long terms accuracy and stability\n Long Life Electrochemical sensor\n Six Gas Analysis in Single Analyzer\n Multi Parameter Single 320 X 240 Graphics LCD Display\n Self diagnostic & Self integrity check\n RS 232/RS 485 and USB Computer Interface\n Excellent low level capability for NOX and SO2 Measurement\n For most of the application sample gas is cooled and dried inside the sampling conditioning systems to avoid the Heated Sample Line.\n Analog 4-20mA output for each gas\n Software solutions for Gas Analysis\n Web Based Real time data transfer with GSM/GPRS Technology\n\n\nSpecification:\nPrinciple\tElectrochemical, TCD (Thermal Conductivity) , NDIR (Non Dispersive Infrared ), Zirconium and Paramagnetic\nRange\t%V/V, % LEL, PPM, Mg/M3\nResolution\t0.1 Unit or 1 Unit (Application based)\nSampling Method\tAuto Suction\nGas Sampling Probe\tDia 8mm SS 316\nDisplay\t320 X 264 Graphic LCD\nAlarm\tRelay Contact NO NC\nAnalog Output\t4-20mA\nDigital Out Put\tRS 232, RS 485 and Modbus Communication Protocol\nPower Source\t230VAC\nAccuracy\t/2%\nResponse Time\t<5 Second\nData Storage\t5000 or 10000\nComputer Interface\tRS 232, USB, RS485\nSensor Life\t2-3 Years\nEnvironmental\t\nTemperature\t15degree Celsius\nHumidity\t< 85%RH\nAtmosphere Pressure\t86- 106Kpa\nDimension in mm\t430 (W) X 150(H) X 250(D)\nWeight\t2.5 KG\nWarranty\tOne Year\n\n\n",
"price": 145500.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 7,
"_keywords": [
"Graphics LCD Display",
"application sample gas",
"Emissions Gas Analyzer",
"duel wavelength sensor",
"Non Dispersive Infrared",
"Real time data transfer",
"Long Life Electrochemical",
"High performance operation",
"Internal Pump draw gas sample",
"adjustable level relay output",
"Excellent low level capability",
"Duel wavelength Infra red sensor",
"208A Continuous Emission Analyzer",
"Special gas sample Conditioning systems",
"Multi Parameter Single 320 X 240 Graphics LCD"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 37,
"imageuri": "https://productimages.withfloats.com/actual/5b8500cfeef0c7054a8de3d5.jpg",
"tileimageuri": "https://productimages.withfloats.com/actual/5b8500cfeef0c7054a8de3d5.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2018-08-11T09:01:41.802Z",
"updatedon": "2018-08-28T07:59:11Z",
"buyonlinelink": null,
"producturl": "http://WWW.APPLIEDTECHNOSYSTEM.IN/products/emissions-gas-analyzer/37",
"availableunits": -1.0,
"iscodavailable": true,
"isprepaidonlineavailable": false,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": null,
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": null,
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "5b6ea2cdd984640544d3903a",
"fptag": "APPLIEDTECHNOSYSTEMS",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "SO2 Gas Analyser",
"description": "Continuous SO2 Gas Anayser\n\nApplied Techno Systems Manufacturer of Gas Analyzer, Gas Detectors, Continuous Emission Monitoring Systems with CPCB norms\n\nSpecification:\n\nPrinciple Electrochemical, TCD (Thermal Conductivity) , NDIR (Non Dispersive Infrared ), Zirconium and Paramagnetic\n\nRange: PPM, Mg/M3\n\nResolution 0.1 Unit or 1 Unit (Application based)\n\nSampling Method Auto Suction\n\nGas Sampling Probe Dia 8mm SS 316\n\nDisplay 320 X 264 Graphic LCD\n\nAlarm Relay Contact NO NC\n\nAnalog Output 4-20mA\n\nDigital Out Put RS 232, RS 485 and Modbus Communication Protocol\n\nPower Source 230VAC\n\nAccuracy /2%\n\nResponse Time\n\nData Storage 5000 or 10000\n\nComputer Interface RS 232, USB, RS485\n\nSensor Life 2-3 Years\n\nEnvironmental\n\nTemperature 15degree Celsius\n\nHumidity < 85%RH\n\nAtmosphere Pressure 86- 106Kpa\n\nDimension in mm 430 (W) X 150(H) X 250(D)\n\nWeight 2.5 KG\n\nWarranty One Year",
"price": 425000.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 7,
"_keywords": [
"Put RS 232",
"Gas Analyzer",
"Manufacturer",
"Gas Detectors",
"Relay Contact",
"Electrochemical",
"SO2 Gas Analyser",
"Interface RS 232",
"320 X 264 Graphic",
"Continuous SO2 Gas",
"Modbus Communication",
"Thermal Conductivity",
"Non Dispersive Infrared",
"Sampling Probe Dia 8mm SS",
"Continuous Emission Monitoring"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 36,
"imageuri": "https://productimages.withfloats.com/actual/5b85020dab5f1f054aa743fe.jpg",
"tileimageuri": "https://productimages.withfloats.com/actual/5b85020dab5f1f054aa743fe.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2018-08-11T08:48:13.147Z",
"updatedon": "2018-08-28T08:04:29Z",
"buyonlinelink": null,
"producturl": "http://WWW.APPLIEDTECHNOSYSTEM.IN/products/so2-gas-analyser/36",
"availableunits": -1.0,
"iscodavailable": true,
"isprepaidonlineavailable": false,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": null,
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": null,
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "5b6d4da1a65fa004f7667f39",
"fptag": "APPLIEDTECHNOSYSTEMS",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "HF Gas Analyser",
"description": "Continuous HF Analyzer Model ATS-208A For SSP (Single Super Phospahate) Plant\n\n. Features\n\n· Microcontroller based embedded intelligent instruments\n\n· Continuous Monitoring of HF\nLong Life Electrochemical sensor\nMulti Parameter Single 320 X 240 Graphics LCD Display\n\n· Self diagnostic & Self integrity check\n\n· RS 232/RS 485 and USB Computer Interface\n\n· For most of the application sample gas is cooled and dried inside the sampling conditioning systems to avoid the Heated Sample Line.\n\n· Analog 4-20mA output for each gas\n\n· Software solutions for Gas Analysis\n\n· Web Based Real time data transfer\n\n· Model ATS- 208A Emission Analyzer continuously monitors the concentration of HF ranging from PPM level. Feature includes a duel wavelength sensor, Remote Sampling, Graphics LCD Display, adjustable level relay output for alarm and 4-20mA output for control purpose and minimal maintenance.\n\nSpecial gas sample Conditioning systems are used to clean and dry the gas sample for accurate and High performance operation. An Internal Pump draw gas sample into the sensor through a dust particle filter from an intake which can be located at distance up to 40 meter form the monitor.\n\nThe Sensor and Electronic component are housed in tough aluminium housing\n\nSpecifications:\n\nPrinciple: Electrochemical,\n\nRange: 0-10/50PPM\n\nResolution: 0.1 Unit or 1 Unit (Application based)\n\nSampling Method: Auto Suction\n\nDisplay: 320 X 264 Graphic LCD\n\nAlarm; Relay Contact NO NC\n\nAnolog Out Put: 4-20mA\n\nDigital Out Put : RS 232, RS 485 and Modbus Comminication Protocol\n\nPower Source:230VAC\n\nAccuracy: /2%\n\nResponse Time:\n\nSensor Life: 2-3 Years\n\nDimension in mm: 430 (W) X 150(H) X 250(D)",
"price": 440500.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": [
"320 X 264 Graphic",
"Graphics LCD Display",
"Life Electrochemical",
"dust particle filter",
"Continuous Monitoring",
"application sample gas",
"208A Emission Analyzer",
"duel wavelength sensor",
"Single Super Phospahate",
"High performance operation",
"Continuous HF Analyzer Model",
"Internal Pump draw gas sample",
"adjustable level relay output",
"gas sample Conditioning systems",
"Parameter Single 320 X 240 Graphics LCD"
],
"isarchived": false,
"isavailable": false,
"applicationid": null,
"productindex": 35,
"imageuri": "https://productimages.withfloats.com/actual/5b8501bc3cb3d6054472ba16.jpg",
"tileimageuri": "https://productimages.withfloats.com/actual/5b8501bc3cb3d6054472ba16.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2018-08-10T08:32:33.881Z",
"updatedon": "2018-08-28T08:03:08Z",
"buyonlinelink": null,
"producturl": "http://WWW.APPLIEDTECHNOSYSTEM.IN//hf-gas-analyser/35",
"availableunits": -1.0,
"iscodavailable": true,
"isprepaidonlineavailable": false,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": null,
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": null,
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "5b6b3ac7d657ba05485351f5",
"fptag": "APPLIEDTECHNOSYSTEMS",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "On Line Stack Gas Analyser",
"description": "Online Stack Gas Analyser\nApplied Techno Systems Model ATS- 208A Online Emission Analyzer, continuously monitors the concentration of Flue gases ranging from 100%V/V down to PPM level. Feature includes a duel wavelength sensor, Remote Sampling, Graphics LCD Display, adjustable level relay output for alarm and 4-20mA output for control purpose and minimal maintenance.\n\nSpecial gas sample Conditioning systems are used to clean and dry the gas sample for accurate and High performance operation. An Internal Pump draw gas sample into the sensor through a dust particle filter from an intake which can be located at distance up to 40 meter form the monitor.\n\nOnline Data transmission to CPCB & SPCB through GPRS/GSM technology\n\nSpecifications:\n\n Principle: Electrochemical, TCD (Thermal Conductivity) , NDIR (Non Dispersive Infrared ), Zirconium and Paramagnetic\n Range: %V/V, % LEL, PPM, Mg/M3\n Resolution: 0.1 Unit or 1 Unit (Application based)\n Sampling Method: Auto Suction\n Display: 320 X 264 Graphic LCD\n Alarm; Relay Contact NO NC\n Analog Output: 4-20mA\n Digital Output : RS 232, RS 485 and Modbus Communication Protocol\n Power Source:230VAC\n Accuracy: /2%\n Response Time: <5 Second\n Sensor Life: 2-3 Years\n Temperature:-15degree Celsius Humidity :< 85%RH Atmosphere Pressure: 86- 106Kpa\n Dimension in mm: 430 (W) X 150(H) X 250(D)\n Weight: 2.5 KG\n Warranty: One Year",
"price": 325800.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 7,
"_keywords": [
"Online Stack Gas",
"320 X 264 Graphic",
"Graphics LCD Display",
"dust particle filter",
"Thermal Conductivity",
"Modbus Communication",
"duel wavelength sensor",
"RH Atmosphere Pressure",
"Line Stack Gas Analyser",
"Non Dispersive Infrared",
"High performance operation",
"Internal Pump draw gas sample",
"adjustable level relay output",
"208A Online Emission Analyzer",
"gas sample Conditioning systems"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 34,
"imageuri": "https://productimages.withfloats.com/actual/5c11f4b04448ae0001db8203.jpg",
"tileimageuri": "https://productimages.withfloats.com/actual/5c11f4b04448ae0001db8203.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2018-08-08T09:09:42.735Z",
"updatedon": "2018-12-13T05:57:04Z",
"buyonlinelink": null,
"producturl": "http://WWW.APPLIEDTECHNOSYSTEM.IN//on-line-stack-gas-analyser/34",
"availableunits": -1.0,
"iscodavailable": true,
"isprepaidonlineavailable": false,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": null,
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": null,
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "5b6b3ac6d657ba0548535186",
"fptag": "APPLIEDTECHNOSYSTEMS",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Gas Analyzer",
"description": "Continuous Emissions Analyzer Model ATS-208A\n\nFeatures\n\n· Micro controller based embedded intelligent instruments\n\n· Continuous Monitoring of CO2 ,CH4, CO, O2, SO2, NOX (NO NO2), H2, H2S, N2\n\n· Duel wavelength Infra red sensor for Long terms accuracy and stability\n\n· Long Life Electrochemical sensor\n\n· Six Gas Analysis in Single Analyser\n\n· Multi Parameter Single 320 X 240 Graphics LCD Display\n\n· Self diagnostic Self integrity check\n\n· RS 232/RS 485 and USB Computer Interface\n\n· Excellent low level capability for NOX and SO2 Measurement\n\n· For most of the application sample gas is cooled and dried inside the sampling conditioning systems to avoid the Heated Sample Line.\n\n· Analog 4-20mA output for each gas\n\n· Software solutions for Gas Analysis\n\n· Web Based Real time data transfer with GSM/GPRS Technology\n\nModel ATS- 208A Emission Analyzer continuously monitors the concentration of gases ranging from 100%V/V down to PPM level. Feature includes a duel wavelength sensor, Remote Sampling, Graphics LCD Display, adjustable level relay output for alarm and 4-20mA output for control purpose and minimal maintenance.\n\nSpecial gas sample Conditioning systems are used to clean and dry the gas sample for accurate and High performance operation. An Internal Pump draw gas sample into the sensor through a dust particle filter from an intake which can be located at distance up to 40 meter form the monitor.\n\nThe Sensor and Electronic component are housed in tough aluminium housing\n\nSpecifications:\n\nPrinciple: Electrochemical, TCD (Thermal Conductivity) , NDIR (Non Dispersive Infrared ), Zirconium and Paramagnetic\n\nRange: %V/V, % LEL, PPM, Mg/M3\n\nResolution: 0.1 Unit or 1 Unit (Application based)\n\nSampling Method: Auto Suction\n\nDisplay: 320 X 264 Graphic LCD\n\nAlarm; Relay Contact NO NC\n\nAnolog Out Put: 4-20mA\n\nDigital Out Put : RS 232, RS 485 and Modbus Comminication Protocol\n\nPower Source:230VAC\n\nAccuracy: /2%\n\nResponse Time:\n\nSensor Life: 2-3 Years for Electrochemical 5 Year for NDIR\n\nEnvironmental:\nTemperature:-15degree Celsius Humidity :< 85%RH Atmosphere Pressure: 86- 106Kpa",
"price": 135500.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 7,
"_keywords": [
"Graphics LCD Display",
"application sample gas",
"duel wavelength sensor",
"208A Emission Analyzer",
"Electrochemical 5 Year",
"Non Dispersive Infrared",
"Long Life Electrochemical",
"High performance operation",
"Internal Pump draw gas sample",
"adjustable level relay output",
"Self diagnostic Self integrity",
"Excellent low level capability",
"gas sample Conditioning systems",
"Continuous Emissions Analyzer Model",
"Multi Parameter Single 320 X 240 Graphics LCD"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 28,
"imageuri": "https://productimages.withfloats.com/actual/5b62be326695d305b3721a7a.jpg",
"tileimageuri": "https://productimages.withfloats.com/actual/5b62be326695d305b3721a7a.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2018-08-02T08:17:54.39Z",
"updatedon": "2018-08-08T18:47:34Z",
"buyonlinelink": null,
"producturl": "http://WWW.APPLIEDTECHNOSYSTEM.IN/products/gas-analyzer/28",
"availableunits": -1.0,
"iscodavailable": true,
"isprepaidonlineavailable": false,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "Gas Analyzer",
"tags": [
"Gas Analyzer",
"Continuous Gas Monitor",
"Gas Monitoring System",
"Continuous Emissions Analyzer"
],
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": null,
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": null,
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "5b6b3ac6d657ba0548535180",
"fptag": "APPLIEDTECHNOSYSTEMS",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Chlorine Gas Analayzer",
"description": "Chlorine Gas Analyzer\nModel ATS- 208A Chlorine Gas Analyzer continuously monitors the concentration of Chlorine in PPM and other gases ranging from 100%V/V down to PPM level. Feature includes a duel wavelength sensor, Remote Sampling, Graphics LCD Display, adjustable level relay output for alarm and 4-20mA output for control purpose and minimal maintenance.\n\nSpecial gas sample Conditioning systems are used to clean and dry the gas sample for accurate and High performance operation. An Internal Pump draw gas sample into the sensor through a dust particle filter from an intake which can be located at distance up to 40 meter form the monitor.\n\nSpecifications:\n\nPrinciple: Electrochemical, TCD (Thermal Conductivity) , NDIR (Non Dispersive Infrared ), Zirconium and Paramagnetic\n\n\n•Range: %V/V, % LEL, PPM, Mg/M3\n•Resolution: 0.1 Unit or 1 Unit (Application based)\n•Sampling Method: Auto Suction\n•Display: 320 X 264 Graphic LCD\n•Alarm; Relay Contact NO NC\n•Analog Out Put: 4-20mA\n•Digital Out Put : RS 232, RS 485 and Modbus Communication Protocol\n•Power Source:230VAC\n•Accuracy: /2%\n•Response Time: Sensor Life: 2-3 Years\n•Temperature:-15degree Celsius Humidity :< 85%RH Atmosphere Pressure: 86- 106Kpa\n•Dimension in mm: 430 (W) X 150(H) X 250(D)\n•Weight: 2.5 KG",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 7,
"_keywords": [
"Celsius Humidity",
"320 X 264 Graphic",
"Graphics LCD Display",
"dust particle filter",
"Modbus Communication",
"Thermal Conductivity",
"Chlorine Gas Analayzer",
"duel wavelength sensor",
"RH Atmosphere Pressure",
"Non Dispersive Infrared",
"208A Chlorine Gas Analyzer",
"High performance operation",
"Internal Pump draw gas sample",
"adjustable level relay output",
"gas sample Conditioning systems"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 27,
"imageuri": "https://productimages.withfloats.com/actual/5b62bcf572f606052742007c.jpg",
"tileimageuri": "https://productimages.withfloats.com/actual/5b62bcf572f606052742007c.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2018-08-02T08:12:37.082Z",
"updatedon": "2018-08-08T18:47:34Z",
"buyonlinelink": null,
"producturl": "http://WWW.APPLIEDTECHNOSYSTEM.IN/products/chlorine-gas-analayzer/27",
"availableunits": -1.0,
"iscodavailable": true,
"isprepaidonlineavailable": false,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "Gas Analyzer",
"tags": [
"Gas Analyzer",
"Chlorine Gas Monitoring System",
"Online Gas Analyzer",
"Fixed Chlorine Gas Monitoring",
"Chlorine Gas Analyzer",
"Chloring Gas Monitor"
],
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": null,
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": null,
"gstslab": 0.0,
"isnotforsale": false
},
{
"_id": "67860f1564562081687aa3ee",
"fptag": "APPLIEDTECHNOSYSTEMS",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "CO2 Gas Analyzer ",
"description": "A CO2 Gas Analyzer is a specialized device designed to measure the concentration of carbon dioxide (CO2) in gases, such as in the air or exhaust gases from combustion processes. These analyzers are used in various industries and applications, including environmental monitoring, industrial process control, and scientific research.",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 5,
"_keywords": [
"exhaust gases",
"scientific research",
"combustion processes",
"carbon dioxide co2",
"specialized device designed",
"co2 gas analyzer"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 89,
"imageuri": "",
"tileimageuri": "",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2025-01-14T07:15:33.741Z",
"updatedon": "2025-01-14T07:15:33.741Z",
"buyonlinelink": null,
"producturl": "http://WWW.APPLIEDTECHNOSYSTEM.IN//co2-gas-analyzer-/89",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": false,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": null,
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": null,
"paymenttype": "None",
"producttype": "products",
"hsncode": null,
"gstslab": 0.0,
"isnotforsale": false
}
],
"hasmoreitems": false,
"isapirequest": false,
"totalresults": 27,
"query": null,
"floatingpoint": null
}