Preview

This is your website preview.

Currently it only shows your basic business info. Start adding relevant business details such as description, images and products or services to gain your customers attention by using Boost 360 android app / iOS App / web portal.

APPLIEDTECHNOSYSTEMS 590481e09e768b0560d08878 Products https://www.appliedtechnosystem.in
{ "products": [ { "_id": "5ba33e3be42f7e0001bcc3dd", "fptag": "APPLIEDTECHNOSYSTEMS", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "Fixed Type Nitrogen dioxide Gas Leak Detector ATS 105M", "description": "Fixed Type Nitrogen dioxide Gas Leak Detector - ATS 105M (NOx Analyzer)\n\nModel ATS 105M single channel digital control modules are designed to supervise and display the satus of a single intergal or remote sensor Model ATS 109TD assembly. Model ATS 109TD is housed in a NEMA 4 x wall mount enclosure or Ex -proof enclosure. Model ATS 105M Single channel controllers interface with industry standred two or three wire 4-20mA sensor or other standred voltage / current sensor transmitters and provide the user with concentration display and two independent adjustable alarms levels. The Graphics display can read the concentration. LEDs on the front panel provide indication of all three alarms.\n\nThe alarm relays can be programmed to be either latching or non-latching and to activate either as a rising or failing alarm. The relays are SPDT Form C type rated at 5 Amps. to provide direct alarm action, reducing the need for interposing relays . Local Alarm devices can be connected to the configurable on board alarms.The Fail safe supervisory provides a reliable indicaiton that the Monitor is fully operational. The \"Fail Safe\" design monitors the input power and sttaus of the Power suppy for the e amplifiers.A failure of any one of these functions illuminates a \" Fault\" Light Emitting Diode.\n\nSpecification:\nMinium Resolution: 0.1 or 1 unit of the range\nIndication: Digital Continuous\nMounting: wall\nSensor Technology: Appropriate to Application\nDetection Method: Diffusion / Sample Draw Pump\nAccuracy: +/- 2%\nLinearity: +/- 2%\nRelative Humidity: 0-99 % Non-condensing\nResponse Time: ( 90% in 10 seconds)\nsingal Output for Recorder: 0- IV,420 mA (Optional)\nAlarm Setting: High and very High Adjustable over full range\nAlarmCircuits: SPDT 5 AMP 220V Contacts\nControls: Zero , Span, Alarm setting", "price": 35500.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 7, "_keywords": null, "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 66, "imageuri": "https://productimages.withfloats.com/actual/5c11f39010ec3d000193ee0f.jpg", "tileimageuri": "https://productimages.withfloats.com/actual/5c11f39010ec3d000193ee0f.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2018-09-20T06:29:15.96Z", "updatedon": "2018-12-13T05:52:15Z", "buyonlinelink": null, "producturl": "http://WWW.APPLIEDTECHNOSYSTEM.IN/products/fixed-type-nitrogen-dioxide-gas-leak-detector-ats-105m/66", "availableunits": -1.0, "iscodavailable": true, "isprepaidonlineavailable": false, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": null, "category": "Gas Leak Detection System", "tags": [ "Gas Leak Detection System", "Gas Analyzer", "NOx Leak Detector", "Gas Leak Monitoring System", "Fixed Type Nitrogen dioxide Gas Leak Detector", "SOx Leak Detector" ], "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": null, "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": null, "gstslab": 0.0, "isnotforsale": false }, { "_id": "671a3d6ef363c75e9da48bca", "fptag": "APPLIEDTECHNOSYSTEMS", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "Portable Biogas Analyzer Model ATS 201A", "description": " Portable biogas analyzer Model ATS 201A is a compact, lightweight device designed to measure the composition of biogas, a renewable energy source produced through the anaerobic digestion of organic matter. These analyzers are essential tools for biogas producers, researchers, and quality control professionals.\n\nKey Components and Functions:\nGas Sampling Unit: This component extracts a representative sample of biogas from the production process.\n various gases present in biogas, including:\nMethane (CH4): The primary component of biogas, responsible for its energy content.\nCarbon dioxide (CO2): A byproduct of the digestion process that can reduce the overall energy value of biogas.\nHydrogen sulfide (H2S): A corrosive gas that can damage equipment and contaminate downstream processes.\nOxygen (O2): The presence of oxygen can inhibit the anaerobic digestion process.\nData Processing Unit: This unit processes the sensor signals to provide accurate and reliable measurements of the gas concentrations.\nDisplay: The analyzer typically features a display screen that shows the measured gas concentrations in real-time.\nCommunication Interface: Many analyzers offer connectivity options, such as Bluetooth or Wi-Fi, allowing for data transfer to computers or mobile devices.\nApplications of Portable Biogas Analyzers:\nBiogas Production: Monitoring biogas quality to ensure optimal efficiency and prevent equipment damage.\nResearch and Development: Studying the factors influencing biogas production and developing new technologies.\nQuality Control: Verifying the purity and energy content of biogas before it is used for heating, electricity generation, or fuel.\nEnvironmental Monitoring: Assessing the environmental impact of biogas production and emissions.\nBenefits of Using Portable Biogas Analyzers:\nPortability: Easy to transport and use in various locations.\nAccuracy: Provides reliable measurements of gas concentrations.\nEfficiency: Streamlines biogas quality control processes.\nCost-Effectiveness: Can help identify and address issues that may affect biogas production efficiency.", "price": 0.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 0, "_keywords": [ "various gases", "corrosive gas", "data transfer", "display screen", "mobile devices", "sensor signals", "Carbon dioxide", "Key Components", "organic matter", "Many analyzers", "energy content", "essential tools", "equipment damage", "new technologies", "Hydrogen sulfide", "biogas producers", "primary component", "various locations", "Gas Sampling Unit", "optimal efficiency", "gas concentrations", "production process", "environmental impact", "connectivity options", "downstream processes", "Data Processing Unit", "overall energy value", "reliable measurements", "representative sample", "electricity generation", "Communication Interface", "renewable energy source", "Environmental Monitoring", "Portable Biogas Analyzers", "anaerobic digestion process", "compact, lightweight device", "biogas production efficiency", "quality control professionals", "biogas quality control processes", "Portable Biogas Analyzer Model ATS 201A" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 86, "imageuri": "https://bizimages.withfloats.com/actual/3c2ab3d71ea0442e8142e38f0f096b7d.jpg", "tileimageuri": "https://bizimages.withfloats.com/actual/3c2ab3d71ea0442e8142e38f0f096b7d.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2024-10-24T12:28:30.388Z", "updatedon": "2024-10-24T12:28:30.388Z", "buyonlinelink": null, "producturl": "http://WWW.APPLIEDTECHNOSYSTEM.IN/products/portable-biogas-analyzer-model-ats-201a/86", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": true, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": "ATS 201A", "category": "Biogas Analyzer", "tags": [], "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": "", "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": "", "gstslab": 18.0, "isnotforsale": false }, { "_id": "5ba349358ecf650001949108", "fptag": "APPLIEDTECHNOSYSTEMS", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "Fixed Sulfur Dioxide Gas Leak Monitor - Model ATS 105M", "description": "Fixed Type Sulfar Dioxide Gas Leak Monitor - Model ATS 105M\nThe Monitor is a single Gas Multipurpose monitor that combines simplicity and high performance in a low cost,low maintenance package.The rugged NEMA 4X or 7x assembly is suitable for a variety of industrial , commercial and general purpose applications to monitor HAZARDOUS,Toxic gases or oxygen in process Flue Gas or Ambient Air.\n\nSpecial Features:\nFast and accurate response, Long Life Application Specific Gas Sensor, Technologies, Solid State Electronics, Continuous Monitoring,Two Alarm Levels, Fail Safe Protection, Recorder Output, Integral or Remote Mounting Sensor, Un-attended Operation, Sampling by Diffusion or sample Draw Pump.Flexibility to fit your application needs, Interfaces with Industry Standard Tranmitters.\n\nSpecification:\nMinium Resolution: 0.1 or 1 unit of the range\nIndication: Digital Continuous\nMounting: wall\nSensor Technology: Appropriate to Application\nDetection Method: Diffusion / Sample Draw Pump\nAccuracy: +/- 2%\nLinearity: +/- 2%\nRelative Humidity: 0-99 % Non-condensing\nResponse Time: ( 90% in 10 seconds)\nsingal Output for Recorder: 0- IV,420 mA (Optional)\nAlarm Setting: High and very High Adjustable over full range\nAlarmCircuits: SPDT 5 AMP 220V Contacts\nControls: Zero , Span, Alarm setting\n", "price": 36500.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 7, "_keywords": null, "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 71, "imageuri": "https://productimages.withfloats.com/actual/5c11f201a81ccb00013290d8.jpg", "tileimageuri": "https://productimages.withfloats.com/actual/5c11f201a81ccb00013290d8.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2018-09-20T07:16:05.364Z", "updatedon": "2018-12-13T05:45:37Z", "buyonlinelink": null, "producturl": "http://WWW.APPLIEDTECHNOSYSTEM.IN/products/fixed-sulfur-dioxide-gas-leak-monitor-model-ats-105m/71", "availableunits": -1.0, "iscodavailable": true, "isprepaidonlineavailable": false, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": null, "category": "Fixed Gas Leak Monitor", "tags": [ "Fixed Gas Leak Monitor", "Sulfur Dioxide Gas Leak Monitor" ], "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": null, "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": null, "gstslab": 0.0, "isnotforsale": false }, { "_id": "5ba33ce49ecfd70001a9d308", "fptag": "APPLIEDTECHNOSYSTEMS", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "Online Sulfur Dioxide (SO2) Gas Leak Detector - ATS 105M", "description": "Online Sulfur Dioxide Gas Leak Monitor - Model ATS 105M\nThe Monitor is a single Gas Multipurpose monitor that combines simplicity and high performance in a low cost,low maintenance package.The rugged NEMA 4X or 7x assembly is suitable for a variety of industrial , commercial and general purpose applications to monitor HAZARDOUS,Toxic gases or oxygen in process Flue Gas or Ambient Air.\n\nSpecification:\nMinium Resolution: 0.1 or 1 unit of the range\nIndication: Digital Continuous\nMounting: wall\nSensor Technology: Appropriate to Application\nDetection Method: Diffusion / Sample Draw Pump\nAccuracy: +/- 2%\nLinearity: +/- 2%\nRelative Humidity: 0-99 % Non-condensing\nResponse Time: ( 90% in 10 seconds)\nsingal Output for Recorder: 0- IV,420 mA (Optional)\nAlarm Setting: High and very High Adjustable over full range\nAlarmCircuits: SPDT 5 AMP 220V\tContacts\nControls: Zero , Span, Alarm setting", "price": 35500.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 7, "_keywords": null, "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 64, "imageuri": "https://productimages.withfloats.com/actual/5c11f3740ae3790001c954c6.jpg", "tileimageuri": "https://productimages.withfloats.com/actual/5c11f3740ae3790001c954c6.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2018-09-20T06:23:32.3Z", "updatedon": "2018-12-13T05:51:47Z", "buyonlinelink": null, "producturl": "http://WWW.APPLIEDTECHNOSYSTEM.IN/products/online-sulfur-dioxide-so2-gas-leak-detector-ats-105m/64", "availableunits": -1.0, "iscodavailable": true, "isprepaidonlineavailable": false, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": null, "category": "Gas Analyzer", "tags": [ "Gas Analyzer", "Fixed Gas Monitor", "Gas Leak Detector", "SO2 Analyzer", "SOx Monitor" ], "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": null, "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": null, "gstslab": 0.0, "isnotforsale": false }, { "_id": "6690f37b62369a1a08b058c3", "fptag": "APPLIEDTECHNOSYSTEMS", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "INSITU ZIRCONIA BASED OXYGEN ANALYZER", "description": "FEATURES \n1)Zirconia oxide sensor, giving real measurement of excess oxygen\n2. Long life zirconium Sensor\n3. Reliable out put , adaptable to close loop control\n4. Easy to Operate\n5. Wide Measurement Range 1PPM to 96%\n6. Easy installation, all hardware supplied with the system.\n7. Completely field repairable.\n8. Digital electronics package in IP 65 housing.\n9. Explosion-proof housing available as option.\n10. Auto & manual calibration facility for zirconium sensor.\n11. Micro controller based digital systems with user friendly\nAPPLICATIONS ·\nGas Manufacturing & Testing Petrochemicals & Chemical Industry ·\n· Exhaust Gas Analysis\n· Food Packing Factory\n· Monitor Vehicle Emission\n· Low oxygen Mesurment at industrial Process ·\n· Steel Plant Air Quality Monitoring, Oxygen Monitoring\n· Laboratories & Institutions\n· Metal Processing Plant\n· Petrochemical & Chemical Industries\n· Pharmaceutical Industries \nTECHNICAL SPECIFICATIONS\nPower supply :-24V ±10% Limited Power Supply\nPower consumption :-700mA maximum @ 24V\nAnalog outputs :-Single or Dual 420mA\nOutput ranges (oxygen) :-0— 25% vol.O2\nOutput ranges (pressure):- 750 — 1260mbar absolute\nRelays (SPST, N/O as std.):- 1 x system alarm (SPST)\n 1 x user configurable O set point alarm\nDigital communications :- RS485 Modbus RTU protocol\nDisplay :-16 character, 2 - line, backlit\n\nOPERATING CONDITIONS\nAmbient temperature:- 20 to +55°C (4 to +131°F)\nAmbient relative humidity :-95% RH\nGas composition Combustion gas from natural gas, biogas or oil\nSample gas temperature:- +700°C (1292°F)\nSample gas flow rate :-4m/s minimum recommended\nCompensated pressure :-750 — 1260mbar absolute", "price": 230000.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 0, "_keywords": [ "5% RH", "25% vol", "65 housing", "point alarm", "natural gas", "user friendly", "excess oxygen", "Analog outputs", "Combustion gas", "digital systems", "Gas composition", "Micro controller", "real measurement", "1 x system alarm", "O2 Output ranges", "Chemical Industry", "Easy installation", "Gas Manufacturing", "Power consumption", "Oxygen Monitoring", "industrial Process", "close loop control", "Chemical Industries", "Ambient temperature", "Compensated pressure", "OPERATING CONDITIONS", "Exhaust Gas Analysis", "Low oxygen Mesurment", "Food Packing Factory", "Sample gas flow rate", "1 x user configurable", "Digital communications", "Wide Measurement Range", "Sample gas temperature", "Metal Processing Plant", "Explosion-proof housing", "1)Zirconia oxide sensor", "1260mbar absolute Relays", "Monitor Vehicle Emission", "Dual 420mA Output ranges", "Pharmaceutical Industries", "Ambient relative humidity", "Long life zirconium Sensor", "Digital electronics package", "manual calibration facility", "RS485 Modbus RTU protocol Display", "Steel Plant Air Quality Monitoring", "TECHNICAL SPECIFICATIONS Power supply", "INSITU ZIRCONIA BASED OXYGEN ANALYZER" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 75, "imageuri": "https://bizimages.withfloats.com/actual/895d17c6f4da464e8654f534e6a43f67.jpg", "tileimageuri": "https://bizimages.withfloats.com/actual/895d17c6f4da464e8654f534e6a43f67.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2024-07-12T09:12:27.465Z", "updatedon": "2024-07-12T09:12:27.465Z", "buyonlinelink": null, "producturl": "http://WWW.APPLIEDTECHNOSYSTEM.IN/products/insitu-zirconia-based-oxygen-analyzer/75", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": true, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": "", "category": "OXYGEN ANALYZER", "tags": null, "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": "", "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": "", "gstslab": 0.0, "isnotforsale": false }, { "_id": "5ba34a638be1ca00010f1a22", "fptag": "APPLIEDTECHNOSYSTEMS", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "Chlorine Gas Detector", "description": "With thorough understanding of the relevant industry, we are offering a wide range of Fixed Gas Detection System. It is suitable for Combustible gases (%LEL) or PPM level of CO,H2S, SO2,NO,NO2,CL2,B2H6, Hydrocarbons, organic solvents and other Toxic Gases. This system is manufactured using best quality raw-material and highly developed technology. In tune with different needs of our copious clients, we customize the entire range in different sizes and other related specifications. Our offered range has gained exceptional value amongst our clients for its defined features.\n\nFeatures:\n\n•Precisely designed \n•Sturdiness\n•Long operational life\nOther Details:\n\n•Model ATS-105M is Single Point Hazardous Gas Monitor/ Alarm for ambient air. Model ATS-105 is suitable for Combustible gases (%LEL) or PPM level of CO, H2S, SO2, NO, NO2, CL2, B2H6, Hydrocarbons, organic solvents and other Toxic Gases. \n•The ATS-105M features a rugged, long-life Electrochemical, Catalytic Pellister, metal oxide semiconductor (MOS) sensor. \n•The sensor is available either in a separate junction box for remote mounting up to several hundred Meters from the monitor, or as an integral component attached to the instrument. \n•The ATS-105M provides a Graphics LCD display of gas concentrations, audio/visual alarms, relay contacts, plus analog (4-20mA ) and digital RS 232/485 and USB outputs. Accept Single 4-20 mA Input from Remote Sensor/Transmitter. \nSpecification:\nPrinciple Electrochemical, Solid State Semiconductor Catalytic and PID\n\nRange PPM/PPB or mg/M3\n\nResolution 0.1 Unit or 1 Unit (Application based)\n\nSampling Method Diffusion\n\nDisplay 128 X 64 Graphics LCD\n\nAlarm Relay Contact NO+NC\n\nAnalog out Put 4-20mA\n\nDigital out Put RS 232, RS 485 and Modbus Communication Protocol\n\nPower Source 230V AC\n\nAccuracy +/2%\n\nResponse Time\n\nData Storage 1000 or 10000\n\nSensor Life 2-3 Years\n\nEnvironmental\n\nTemperature 15 degree Celsius\n\nHumidity < 85%RH\n\nAtmosphere Pressure 86- 106Kpa\n\nDimension in mm 210 (W) X 180(H) X 110(D)\n\nWeight 1.2 KG\n\nWarranty One Year", "price": 36500.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 7, "_keywords": null, "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 72, "imageuri": "https://productimages.withfloats.com/actual/5c11f21ff323430001931f43.jpg", "tileimageuri": "https://productimages.withfloats.com/actual/5c11f21ff323430001931f43.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2018-09-20T07:21:07.972Z", "updatedon": "2018-12-13T05:46:07Z", "buyonlinelink": null, "producturl": "http://WWW.APPLIEDTECHNOSYSTEM.IN/products/chlorine-gas-detector/72", "availableunits": -1.0, "iscodavailable": true, "isprepaidonlineavailable": false, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": null, "category": "Chlorine Leak Detector", "tags": [ "Chlorine Leak Detector", "Gas Leak Detector", "Fixed Gas Leaak dETECTIOR" ], "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": null, "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": null, "gstslab": 0.0, "isnotforsale": false }, { "_id": "5ba33da09679aa00015c283c", "fptag": "APPLIEDTECHNOSYSTEMS", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "Online Nitrogen Oxide (NO2) Gas Leak Detector ATS 105M", "description": "Online Nitrogen Oxide (NO2) Gas Leak Detector ATS 105M\n\nModel ATS 105M single channel digital control modules are designed to supervise and display the satus of a single intergal or remote sensor Model ATS 109TD assembly. Model ATS 109TD is housed in a NEMA 4 x wall mount enclosure or Ex -proof enclosure. Model ATS 105M Single channel controllers interface with industry standred two or three wire 4-20mA sensor or other standred voltage / current sensor transmitters and provide the user with concentration display and two independent adjustable alarms levels. The Graphics display can read the concentration. LEDs on the front panel provide indication of all three alarms.\n\nThe alarm relays can be programmed to be either latching or non-latching and to activate either as a rising or failing alarm. The relays are SPDT Form C type rated at 5 Amps. to provide direct alarm action, reducing the need for interposing relays . Local Alarm devices can be connected to the configurable on board alarms.The Fail safe supervisory provides a reliable indicaiton that the Monitor is fully operational. The \"Fail Safe\" design monitors the input power and sttaus of the Power suppy for the e amplifiers.A failure of any one of these functions illuminates a \" Fault\" Light Emitting Diode.\n\nSpecification:\n\nMinimum Resolution: 0.1 or 1 unit of the range\nIndication: Digital Continuous\nMounting: wall\nSensor Technology: Appropriate to Application\nDetection Method: Diffusion / Sample Draw Pump\nAccuracy: +/- 2%\nLinearity: +/- 2%\nRelative Humidity: 0-99 % Non-condensing\nResponse Time: ( 90% in 10 seconds)\nSingal Output for Recorder: 0- IV,420 mA (Optional)\nAlarm Setting: High and very High Adjustable over full range\nAlarm Circuits: SPDT 5 AMP 220V Contacts\nControls: Zero , Span, Alarm setting\n", "price": 35500.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 7, "_keywords": null, "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 65, "imageuri": "https://productimages.withfloats.com/actual/5c11f22c0cbfd500019068ef.jpg", "tileimageuri": "https://productimages.withfloats.com/actual/5c11f22c0cbfd500019068ef.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2018-09-20T06:26:40.901Z", "updatedon": "2018-12-13T05:46:19Z", "buyonlinelink": null, "producturl": "http://WWW.APPLIEDTECHNOSYSTEM.IN/products/online-nitrogen-oxide-no2-gas-leak-detector-ats-105m/65", "availableunits": -1.0, "iscodavailable": true, "isprepaidonlineavailable": false, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": null, "category": "NO2 Leak Detector", "tags": [ "NO2 Leak Detector", "NOx Gas Analyzer", "Fixed Type Gas Monitoring System", "Gas Leak Monitor" ], "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": null, "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": null, "gstslab": 0.0, "isnotforsale": false }, { "_id": "5b6ea828b5dfa70508cd4124", "fptag": "APPLIEDTECHNOSYSTEMS", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "Online Stack Monitoring Systems", "description": "\nApplied Techno Systems offer comprehensive range of stack gas Analyzer Portable and Continuous for the analysis of stack/flue gases in exhaust, boiler and combustion process. Model ATS- 206A Flue gas Analyzer measure the flue gases after placing its probe into stack or appliance exhaust and see the concentration of Oxygen (O2), Carbon Monoxide (CO) Carbon Dioxide (CO2). Efficient combustion also reduces emission of pollutants such as nitric oxide (NO), nitrogen dioxide (NO2), sulphur dioxide (SO2), and particulate matter. A gas analyzer will also help measure various gas pollutants in the exhaust for environmental reasons.\n\n· Microcontroller based embedded intelligent instruments\n\n· Continuous Monitoring of CO2 ,CH4, CO, O2, SO2, NOX (NO NO2), H2, H2S, N2\n\n· Duel wavelength Infra red sensor for Long terms accuracy and stability\n\n· Long Life Electrochemical sensor\n\n· Six Gas Analysis in Single Analyser\n\n· Multi Parameter Single 320 X 240 Graphics LCD Display\n\n· Self diagnostic & Self integrity check\n\n· RS 232/RS 485 and USB Computer Interface\n\n· Excellent low level capability for NOX and SO2 Measurement\n\n· For most of the application sample gas is cooled and dried inside the sampling conditioning systems to avoid the Heated Sample Line.\n\n· Analog 4-20mA output for each gas\n\nModel ATS- 208A Emission Analyzer continuously monitors the concentration of gases ranging from 100%V/V down to PPM level. Feature includes a duel wavelength sensor, Remote Sampling, Graphics LCD Display, adjustable level relay output for alarm and 4-20mA output for control purpose and minimal maintenance.\n\nSpecial gas sample Conditioning systems are used to clean and dry the gas sample for accurate and High performance operation. An Internal Pump draw gas sample into the sensor through a dust particle filter from an intake which can be located at distance up to 40 meter form the monitor.\n\nThe Sensor and Electronic component are housed in tough aluminium housing\n\nSpecifications:\n\nPrinciple: Electrochemical, TCD (Thermal Conductivity) , NDIR (Non Dispersive Infrared ), Zirconium and Paramagnetic\n\nRange: %V/V, % LEL, PPM, Mg/M3\n\nResolution: 0.1 Unit or 1 Unit (Application based)\n\nSampling Method: Auto Suction\n\nDisplay: 320 X 264 Graphic LCD", "price": 325100.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 0, "_keywords": [ "Graphics LCD Display", "320 X 264 Graphic LCD", "application sample gas", "duel wavelength sensor", "208A Emission Analyzer", "Long Life Electrochemical", "High performance operation", "stack gas Analyzer Portable", "Internal Pump draw gas sample", "adjustable level relay output", "206A Flue gas Analyzer measure", "measure various gas pollutants", "Excellent low level capability", "gas sample Conditioning systems", "Multi Parameter Single 320 X 240 Graphics LCD" ], "isarchived": false, "isavailable": false, "applicationid": null, "productindex": 38, "imageuri": "https://productimages.withfloats.com/actual/5b8500c6016722053c706450.jpg", "tileimageuri": "https://productimages.withfloats.com/actual/5b8500c6016722053c706450.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2018-08-11T09:11:04.461Z", "updatedon": "2018-08-28T07:59:01Z", "buyonlinelink": null, "producturl": "http://WWW.APPLIEDTECHNOSYSTEM.IN/products/online-stack-monitoring-systems/38", "availableunits": -1.0, "iscodavailable": true, "isprepaidonlineavailable": false, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": null, "category": "stack monitoring system", "tags": [ "stack monitoring system", "gas analyzer", "continuous emission monitoring systems" ], "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": null, "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": null, "gstslab": 0.0, "isnotforsale": false }, { "_id": "6713a3888b4c7e5cfcc106be", "fptag": "APPLIEDTECHNOSYSTEMS", "merchantname": null, "customwidgets": null, "externalsourceid": null, "name": "Portable Dew Point Meter Model ATS 301D", "description": "Portable dew point meter Model ATS 301D used to measure the dew point temperature of a gas or air sample. It operates by cooling a surface until water vapor in the sample condenses into liquid droplets. The temperature at which this condensation occurs is the dew point.   \n\nHere's how a dew point meter works:\n\nSample Collection: The meter draws in a sample of the gas or air to be measured.\nCooling: The sample is passed over a cooled surface, such as a mirror or a chilled plate.   \nCondensation: As the surface cools, the water vapor in the sample reaches its saturation point and begins to condense into liquid droplets.   \nMeasurement: The temperature of the surface at the point of condensation is recorded as the dew point.\n\n   \n", "price": 0.0, "discountamount": 0.0, "currencycode": "INR", "priority": 1000000, "isfreeshipmentavailable": false, "shipmentduration": 0, "_keywords": [ "air sample", "water vapor", "cooled surface", "liquid droplets", "saturation point", "Sample Collection", "dew point temperature", "Portable Dew Point Meter Model ATS 301D" ], "isarchived": false, "isavailable": true, "applicationid": null, "productindex": 85, "imageuri": "https://bizimages.withfloats.com/actual/0c8fc8fd5f154f108f0a7e13f86fb160.jpg", "tileimageuri": "https://bizimages.withfloats.com/actual/0c8fc8fd5f154f108f0a7e13f86fb160.jpg", "images": null, "totalqueries": 0, "gpid": null, "groupproductid": null, "createdon": "2024-10-19T12:18:16.324Z", "updatedon": "2024-10-19T12:18:16.324Z", "buyonlinelink": null, "producturl": "http://WWW.APPLIEDTECHNOSYSTEM.IN/products/portable-dew-point-meter-model-ats-301d/85", "availableunits": -1.0, "iscodavailable": false, "isprepaidonlineavailable": true, "maxcodorders": 0, "maxprepaidonlineorders": 0, "uniquepaymenturl": null, "brandname": "ATS 301D", "category": "Dew Point & Moisture Analyzer", "tags": [], "variants": false, "keyspecification": null, "otherspecifications": null, "pickupaddressreferenceid": "", "paymenttype": "AssuredPurchase", "producttype": "products", "hsncode": "", "gstslab": 18.0, "isnotforsale": false } ], "hasmoreitems": false, "isapirequest": false, "totalresults": 27, "query": null, "floatingpoint": null }

Still searching for
1 zirconia oxide sensor?

Still searching for
1 zirconia oxide sensor?

Chat with us