CONTINUOUS EMISSIONS MONITORING SYSTEMS (Model ATS - 208A ) manufacturing in india, manufacturing in mumbai Model ATS - 208A Gas Analyzer continuously monitors the concentration of gases ranging from 100%V/V down to PPM level. Feature includes a duel wavelength sensor, Remote Sampling, Graphics LCD Display, adjustable level relay output for alarm and 4-20mA output for control purpose and minimal maintenance. Special gas sample Conditioning systems are used to clean and dry the gas sample for accurate and High performance operation. An Internal Pump draw gas sample into the sensor through a dust particle filter from an intake which can be located at distance up to 40 meter form the monitor. The Sensor and Electronic component are housed in tough aluminium housing For hazardous area applicationsthe sensor may be mounted remotely in the hazardous area and safely connected via anzener barrier to the electronics unit in the safe area. Alternatively the electronicsunit can be supplied in an Explosion proof enclosure. FEATURES: Fully integrated system up to 7 gases in a single compact analyzer. Wide measurement range from 0 - 100 PPM up to 0 - 10, 000 PPM. Widely accepted, cerfied pe ormance complies with the latest monitoring standards. Simple installaon & mai tenance requires no specialist skills or training, all maintenance carried out on-site. Highest measurement performance ultra - low dri measuement technology. Measured Total NOx (NO+NO2) separate sensors for true NOx monitoring. Record and store vital emission data internal data logging funcon. Combuson ciency measuremenment opor a Opmiaaon ocess e ciency where all maintenance carried out on-site condion ae changing APPLICATION: Gas turbines. Power plants. Boiler systems - coal, oil and gas fired. Incinerators - domes c, haardous, clinical and biological waste Wood, sawdust, pellet and bark burners Thermal oxidizers. Pulp and paper. Cement & lime manufacture. Gas pipeline compressors. Bio-fuel power genera on. Petrochemical and refineries. SPECIFICATIONS: Calibration method: Manual or Automatic 2-Point calibration span and zero. DISPLAY: Alpha numeric LCD back light Analogue outputs : Isolated current loops One per gas 4-20 mA. Relays outputs : One per gas Relay rang : Isolated changeover contacts rated 0.5A @ 125V a.c; V d.c Communications : RS 232 or RS 485 Modbus serial digital data bus (2 or 4 wire). Parameters measures: O2, CO, CO2, NO/NOX, SO2, HF, HCL, CL2, CH4, H2, VOC, Efficiency Stack Loss
Submit Your Enquiry